220 Simultaneous measurement of three dimensional (3D) left and right ventricular volumes and ejection fraction during dobutamine cardiovascular magnetic resonance

Introduction

Appropriate displacement of blood volume from the right into the left ventricle via the pulmonary circulation is necessary to maintain forward cardiac output during stress and prevent inappropriate displacement of blood into the lungs by the right ventricle during left ventricular (LV) failure.

Purpose

Cardiovascular magnetic resonance (CMR) has been used to quantify LV and right ventricular (RV) volumes, and ejection fraction (EF) simultaneously at rest, but the feasibility of CMR to quantify simultaneous measures of RV and LV volumes and EF throughout the course of cardiovascular stress testing in humans is unknown.

Methods

Thirteen healthy subjects (5 women; 42%), without medical conditions and taking no medications, aged 53 + 10 years, underwent 2 CMR studies separated by 4 to 8 weeks in which dobutamine and atropine were infused to achieve 85% of the maximum predicted heart rate response (MPHRR) for age. Images were acquired with a 1.5 T Excite (General Electrical Medical Systems, Milwaukee, Wisconsin) whole body imaging system using a phased array a cardiac surface coil over the chest. Multi-slice, steady state free precession cine white blood images were acquired spanning the cardiac base to the apex. Image parameters included an 8 mm thick slice, a 2 mm gap, a 45 cm FOV, a 224 × 160 matrix, a 10 msec repetition time, a 3 msec echo time, a temporal resolution of 20 msec, a 125 Hz/px band-width, and a flip angle of 50 degrees. Two slices were acquired in the multi-slice stack during 10 second periods of breath-holding. RV and LV volumes, and EF were determined using a Simpson's Rule technique in which the endocardial surface was identified at end-diastole and end-systole in each slice and multiplied by the slice thickness and number of slices to determine the volumes for the respective LV and RV cavities.

Results

All data are expressed as mean + standard deviation. At rest, low dose dobutamine (7.5 mcg/kg/min), and peak stress, the heart rates, systolic, and diastolic blood pressures for the participants were 65 + 10, 137 + 16, and 83 + 15; 81 + 13, 39 + 18; and 78 + 13; 134 + 13, 151 + 18, and 71 + 15, respectively on exam 1, and, 64 + 10, 139 + 16, and 80 + 12; 81 + 13, 141 + 16, and 80 + 8; 133 + 10, 155 + 20, and 78 + 11, respectively, on exam 2 (p = 0.003, 0.008, 0.02; 0.004, 0.006, 0.09; 0.11, 0.007, 0.4 for all comparisons of like terms between exam 1 and 2). The RV and LV end-diastolic (EDV), end-systolic (ESV), and stroke volumes (SV), as well as EF for each level of stress during exam 1 and 2 are shown in the Tables (1 & 2). RV and LV SV were highly correlated at each level of stress (rest, r = 0.446; low dose, r = 0.619; peak stress, r = 0.362). Also, the mean difference in SV at each level of stress (rest, p = 0.0007; low dose, p = 0.0012; peak stress, p = 0.0014) was similar between exam 1 and 2.

Conclusion

Simultaneous change in RV and LV stroke volume can be assessed in a highly reproducible manner throughout the course of pharmacologic stress administered to achieve 85% of MPHRR for age. This noninvasive methodology will be useful to further study the interdependence of RV and LV stroke volume during various forms of stress, and identify inappropriate displacement of blood flow into the lungs in patients with dyspnea.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Mandapaka, S., Hamilton, C., Lane, K. et al. 220 Simultaneous measurement of three dimensional (3D) left and right ventricular volumes and ejection fraction during dobutamine cardiovascular magnetic resonance. J Cardiovasc Magn Reson 10 (Suppl 1), A81 (2008). https://doi.org/10.1186/1532-429X-10-S1-A81

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-10-S1-A81

Keywords