Skip to main content

Table 7 Summary of results from patients.

From: T2 quantification for improved detection of myocardial edema

Patient #

Region of infarction

T2 (ms)

T2W (signal intensity)

  

Infarct

Remote

Infarct

Remote

1

Basal inferior

65.7 ± 6.7

46.5 ± 5.5

69 ± 8.6

71 ± 5.5

2

Mid inferior

68.9 ± 3.6

53 ± 3.2

100 ± 6.9

66.3 ± 8.3

3

Mid anterior/anteroseptal/inferoseptal

65.4 ± 2.3

52.1 ± 7

108.3 ± 9.6

48 ± 7.9

  1. T2 measurements were made in a single mid-ventricular short-axis slice.