Skip to main content

Table 5 Diagnostic performance of transverse and longitudinal parameters for detection of depressed RVEF below the median value (< 35%).

From: Right ventricular ejection fraction is better reflected by transverse rather than longitudinal wall motion in pulmonary hypertension

Ā 

AUC*

Standard error

Cutoff value

Sensitivityā€  (%)

Specificityā€  (%)

P-valueā€ 

Transverse measures

fractional SF level mid-4

0.938 [0.892, 0.985]

0.0236

17.7%

84.2

88.1

< 0.001

Ī”SF SF -mid 4

0.906 [0.849, 0.963]

0.0291

7.4 mm

80.7

83.1

< 0.001

Longitudinal measures

fractional TA

0.819 [0.741, 0.896]

0.0397

17.2%

75.4

78.0

< 0.001

TAPSE

0.767 [0.680, 0.854]

0.0442

16.3 mm

70.2

76.3

< 0.001

  1. *Data is shown with the 95% confidence interval within the brackets.
  2. ā€ At receiver operating characteristic curve analysis.