Skip to main content

Table 4 Inter-study reproducibility for LV volumes and function.

From: Reproducibility of adenosine stress cardiovascular magnetic resonance in multi-vessel symptomatic coronary artery disease

  Coefficient of Variation (%)  
Parameter Control Case p*
Left ventricular ejection fraction 2.4 2.7 0.292
Left ventricular end diastolic volume 1.9 4.4 0.018
Left ventricular end systolic volume 6.8 6.4 0.787
Left ventricular stroke volume 2.1 4.2 0.483
Left ventricular mass 4.4 4.0 0.619
  1. *Comparison of CoV between control and case.