Skip to main content

Table 4 Correlation between extend of LGE and histopathological score

From: Accuracy of cardiovascular magnetic resonance in myocarditis: comparison of MR and histological findings in an animal model

 

Turbo-FLASH

Turbo-FLASH with fs

TSE

TSE with fs

histopathological score

r = 0.94;

p < 0.05

r = 0.96;

p < 0.05

r = 0.43;

p = 0.29

r = 0.68;

p = 0.06

  1. Spearman's correlations between extend of LGE measured in different CMR-sequences and histopathological score. (Turbo-FLASH = gradient-echo-sequence; TSE = turbo-spin-echo-sequence; fs = fat saturation).