Skip to main content

Table 4 Inter- and intra-observer variability of the LVEDV and the four LV flow components as a percentage of EDV

From: Semi-automatic quantification of 4D left ventricular blood flow

 

I1 A1

P-value

vs I1 A2

I1 A2

P-value

vs I2

I2

P-value

vs I1 A1

EDV

146 ± 25

NS

151 ± 29

0.010

144 ± 24

NS

Direct flow

30 ± 10%

NS

30 ± 9%

NS

33 ± 11%

NS

Retained inflow

18 ± 4%

NS

18 ± 4%

NS

18 ± 4%

NS

Delayed ejection flow

17 ± 4%

NS

16 ± 4%

NS

16 ± 4%

NS

Residual volume

36 ± 6%

NS

36 ± 6%

NS

33 ± 6%

NS

  1. Mean ± SD for all 9 subjects. P-values < 0.01 are considered statistically significant. EDV, End diastolic volume; NS, Not Significant; I1 A1, Investigator 1 Analysis 1; I1 A2, Investigator 1 Analysis 2; I2; Investigator 2.