Skip to main content

Table 1 Cardiac functional parameters for each method, control mice n = 6.

From: Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modelling

 

Std

GPM

Full

GPM

Six Slice

GPM

Four Slice

Std-GPM

Full

Std-GPM Six Slice

Std-GPM Four Slice

LV mass [mg]

105 ± 14

106 ± 10

104 ± 12

105 ± 7

0.4 ± 5.8

-2.0 ± 7.5

-0.6 ± 5.0

EDV [μl]

64 ± 10

68 ± 10

67 ± 9

67 ± 10

-1.2 ± 6.5

-2.0 ± 7.0

-1.4 ± 9.3

ESV [μl]

24 ± 6

28 ± 5

30 ± 6

29 ± 6

1.6 ± 3.7

3.5 ± 4.7

2.2 ± 5.5

SV [μl]

40 ± 6

39 ± 6

37 ± 6

39 ± 6

-2.8 ± 4.3

-5.4 ± 4.9

-3.6 ± 5.4

EF [%]

63 ± 6

58 ± 4

55 ± 6

57 ± 6

-3.2 ± 3.9

-6.4 ± 5.5

-4.0 ± 4.7

  1. Std: standard analysis; GPM: guide point modelling.