Skip to main content
  • Workshop presentation
  • Open access
  • Published:

Flow-sensitive four-dimensional (4D) magnetic resonance imaging reveals abnormal blood flow pattern in the aorta and pulmonary trunk of patients with transposition of the great arteries operated with atrial baffle switch

Background

Patients with transposition of the great arteries (TGA) after atrial baffle switch operation show differences in ventricular torsion and outflow tract geometry compared to healthy volunteers. We sought to investigate if these differences in cardio-mechanics translate into abnormal blood flow patterns in the pulmonary trunk and the aorta.

Methods

Blood flow patterns were assessed with flow-sensitive four-dimensional velocity-encoded magnetic resonance imaging (4D VEC MRI), using a 1,5T Phillips MRI system. Measurements were made in the pulmonary trunk and the aorta in healthy volunteers (n=7) and TGA patients after atrial baffle switch operation (n=10). Blood flow was analyzed for vortex formation using custom-made software.

Results

There were clear differences in blood flow patterns between healthy volunteers and TGA patients in both the pulmonary trunk and the aorta. In healthy volunteers, flow was laminar, parabolic in the pulmonary trunk and showed left helical flow pattern in the aorta. In TGA patients we observed opposite flow patterns with predominant parabolic flow in the aorta but helical flow and vortex formation in the pulmonary trunk.

Conclusions

There are abnormal flow profiles in the aorta and pulmonary trunk in TGA patients. The data of this study provides evidence that differences in left and right ventricular cardio-mechanics directly translate into different flow patterns.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Nordmeyer, S., Riesenkampff, E., Messroghli, D. et al. Flow-sensitive four-dimensional (4D) magnetic resonance imaging reveals abnormal blood flow pattern in the aorta and pulmonary trunk of patients with transposition of the great arteries operated with atrial baffle switch. J Cardiovasc Magn Reson 14 (Suppl 1), W67 (2012). https://doi.org/10.1186/1532-429X-14-S1-W67

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-14-S1-W67

Keywords