Skip to main content

Table 5 T1-weighted saturation-recovery gradient echo for first pass myocardial perfusion

From: Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease

 

Infant/small child

Large child/adult

In-plane resolution (mm)

1.5-2.0

2.0-2.5

Slice thickness (mm)

5-8

8-10

Image acquisition timing

1 R-R or 2 R-R

1 R-R