- Poster presentation
- Open Access
- Published:
Comparison of feature tracking with harmonic phase imaging analysis for the assessment of diastolic dysfunction
Journal of Cardiovascular Magnetic Resonance volume 15, Article number: E110 (2013)
Background
Diastolic dysfunction (DD) is common in patients with cardiovascular disease. Current cardiac magnetic resonance techniques for assessment of DD require the acquisition of tagged imaging sequences, and complex post-processing. A new post-processing software allows for rapid strain assessment using feature tracking analysis (FT) (TomTec, Diogenes Software, Germany) based on conventional steady-state free precession (SSFP)-Cine sequences. The aim of this study was to compare tagging (TAG) with FT for assessment of diastolic function in patients with DD and healthy controls.
Methods
20 healthy volunteers and 10 patients with echocardiographic diagnosed DD Grade II-III were investigated by the 2 techniques. Cardiovascular magnetic resonance imaging (Philips Intera 1.5T) using CSPAMM and SSFP-Cine sequences was performed for matched mid-ventricular short-axis slices. Each modality was analyzed offline using dedicated post-processing software (Tag Track, Gyrotools, CH for CSPAMM and TomTec for SSFP-Cine) and early-diastolic strain rate (EDSr) was calculated from both datasets. EDSr derived from CSPAMM and SSFP-Cine data were compared and inter-observer and intra-observer variability assessed using Bland-Altman analysis and Pearson correlation coefficient.
Results
For all measurements FT EDSr (78.15+/- 17.17 s-1) was highly correlated with TAG EDSr (76.71+/- 17.45s-1), Bland-Altman analyses for method comparison yielded a mean difference of 1.4 (95% CI: 0.0 to 2.9). Limits of agreement (+/- 1.96 SD) were -14.9 and 12.0. In patients with DD FT EDSr (61.40+/- 15.60s-1) was not significantly different to TAG EDSr (57.60+/- 12.30s-1) (p=ns). The same was found in the control group FT EDSr (86.52+/- 10.55s-1) and TAG (86.27+/- 10.31s-1) (p=ns). Intra-observer variability yielded a mean difference of 1.2+/- 4.9 (FT) and 0.9+/- 3.5 (TAG). Inter-observer variability displayed a mean difference of 2.8+/- 5.84 (FT) and 0.3+/- 3.7 (TAG). Pearson correlation coefficient was (0.96 (FT); 0.97 (TAG)) for intra-observer variability and (0.94 (FT); 0.97 (TAG)) for inter-observer variability.
Conclusions
Assessment of EDSr using a novel feature tracking technique shows good agreement with tagging derived data and may thus be used for rapid clinical determination of diastolic dysfunction. However, compared to feature tracking, tagging revealed lower intra - and inter-observer variability and may therefore remain the preferred technique for research applications.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Doerner, J., Kuetting, D., Sprinkart, A.M. et al. Comparison of feature tracking with harmonic phase imaging analysis for the assessment of diastolic dysfunction. J Cardiovasc Magn Reson 15 (Suppl 1), E110 (2013). https://doi.org/10.1186/1532-429X-15-S1-E110
Published:
DOI: https://doi.org/10.1186/1532-429X-15-S1-E110
Keywords
- Cardiovascular Magnetic Resonance
- Cardiac Magnetic Resonance
- Diastolic Dysfunction
- Feature Tracking
- Cardiovascular Magnetic Resonance Imaging