- Poster presentation
- Open Access
- Published:
Incremental value of cardiac magnetic resonance with adenosine stress perfusion in coronary artery disease detection
Journal of Cardiovascular Magnetic Resonance volume 15, Article number: E57 (2013)
Background
A multiple-test strategy in often needed in the evaluation of patients (pts) with suspected coronary artery disease (CAD). Cardiac magnetic resonance (CMR) has potential advantages in this context allowing simultaneous evaluation of ventricular function, myocardial perfusion and scar detection with high spatial resolution and no ionizing radiation exposure. We aimed to compare the diagnostic accuracy of adenosine stress CMR myocardial perfusion imaging (CMR-MPI) with exercise treadmill test (ETT) for detection of CAD using invasive fractional flow reserve (FFR) as the reference standard, and to assess the best performing diagnostic algorithm using these tests in patients with suspected CAD.
Methods
Prospective single-center study with enrollment of symptomatic pts referred to cardiology to suspected CAD assessment. All pts underwent a sequential protocol including: ETT, CMR-MPI and X-ray coronary angiography (XA). The ETT was dichotomously classified and deemed suggestive of CAD if reproduction of clinical symptoms during effort or additional ST-segment depression ≥1 mm. CMR-MPI exams were evaluated by two independent cardiologists blinded to the results of ETT. Functionally significant CAD was defined by the presence of occlusive/sub-occlusive stenosis or FFR measurements <0.8 in vessels >2 mm. Multiples protocols integrating ETT and CMR-MPI were tested using ROC curves.
Results
80 pts were recruited, 68% male and with mean age of 61 ± 8 years. All pts were symptomatic and had at least one cardiovascular risk factor. CAD was detected in 37 pts (47%). CMR-MPI and ETT showed similar sensitivity for CAD detection (81 vs. 80%), but with higher specificity for CMR-MPI (93 vs. 56%), translating into a greater diagnostic accuracy of CMR-MPI (AUC=0.87 vs. 0.70; PPV=91 vs. 58%). In the best performing protocol (AUC = 0.83), pts with both clinical and electrically positive ETT would be directly referred to XA while all the remaining pts (negative, borderline positive or inconclusive ETT) would be managed according to CMR-MPI results. The other protocols, including referral to CMR-MPI only the pts with borderline positive or inconclusive ETT or with negative or inconclusive ETT had worst performances (AUC=0.75 and 0.73, respectively).
Conclusions
CMR-MPI has high sensitivity and specificity for detection of obstructive CAD. In our pts with high probability of CAD, the inclusion of CMR-MPI in an integrated protocol for the detection of CAD improved the overall diagnostic accuracy, particularly in those pts with negative, borderline positive or inconclusive ETT.
Funding
No conflict of interests/financial disclosures.
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Pereira, E., Bettencourt, N., Ferreira, N.D. et al. Incremental value of cardiac magnetic resonance with adenosine stress perfusion in coronary artery disease detection. J Cardiovasc Magn Reson 15 (Suppl 1), E57 (2013). https://doi.org/10.1186/1532-429X-15-S1-E57
Published:
DOI: https://doi.org/10.1186/1532-429X-15-S1-E57
Keywords
- Coronary Artery Disease
- Cardiac Magnetic Resonance
- Myocardial Perfusion Imaging
- Fractional Flow Reserve
- Obstructive Coronary Artery Disease