Table 3 Results for enlarged ROIs to test for the importance of the accuracy of segmentation

From: Imaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance

Imaging sequence Paired t-test p-value CI95 SNRinjured SNRnon-injured CNR
T2STIR 0.005 8.05-29.9 23.0 17.9 5.1
VISTA 0.009 5.5-27.7 24.3 19.0 5.4
T2prep-GE 0.006 4.4-18.0 21.5 17.3 4.2