Figure 1From: Synchronized cardiac and respiratory sparsity for rapid free-breathing cardiac cine MRI(a) Continuous data acquisition. (b) Cardiac (Car)/respiratory (Res) motion signals detected from the data itself. (c) Data are first sorted using the cardiac signal and then further sorted using the respiratory signal at each cardiac phase, as indicated by the black boxes.Back to article page