Collateral flow quantification by cardiovascular magnetic resonance during continuous submaximal exercise in patients with total cavo-pulmonary connection

Background

Collateral flow is often described in patients with total cavo-pulmonary connection (TCPC). However, the amount of collateral flow in rest and during exercise is unclear. Therefore, the aim of this study was to quantify collateral flow in rest and during continuous submaximal exercise in clinically well doing patients with TCPC.

Methods

Blood flows in the aorta ascendens, aorta descendens, inferior vena cava, and superior vena cava were measured at rest and during continuous submaximal physical exercise by cardiovascular magnetic resonance in 13 patients with TCPC (19±7 yrs.) and 13 age and sex-matched healthy controls (20±8 yrs.).

Results

TCPC patients had significantly lower systemic blood flow(Qs) at rest (2.7±0.6 vs. 3.6±0.7 L/min/m2, p<0.001) and during exercise (3.4±1.0 vs. 4.9±0.9 L/min/m2, p<.0001), than healthy controls. The increase in Qs with exercise was also significantly lower in patients, than in healthy controls (0.6 vs. 1.2 L/min/m2, p<0.02). Absolute collateral flow did not change in TCPC patients during exercise compared to rest (0.4±0.3 vs. 0.5±0.4 L/min/m2, p=0.97).

Conclusions

Clinically well doing patients with TCPC have significant collateral flow at rest (17% of Qs) that does not change during submaximal exercise (14% of Qs).

Funding

N/A.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mkrtchyan, N., Frank, Y., Meierhofer, C. et al. Collateral flow quantification by cardiovascular magnetic resonance during continuous submaximal exercise in patients with total cavo-pulmonary connection. J Cardiovasc Magn Reson 17 (Suppl 1), Q87 (2015). https://doi.org/10.1186/1532-429X-17-S1-Q87

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-17-S1-Q87

Keywords