Dark Blood Imaging of the Heart using Dual-Inversion, Balanced Steady-State Free-Precession
Journal of Cardiovascular Magnetic Resonance volume 18, Article number: P306 (2016)
Background
Dark blood images of the heart are typically acquired using an ECG-gated, single-slice, dual-inversion turbo spin-echo (TSE) pulse sequence. We hypothesized that a dual-inversion balanced steady-state free-precession (DB-bSSFP) pulse sequence might provide more efficient multi-slice coverage with less sensitivity to cardiac motion.
Methods
The study was approved by the institutional review board and written, informed consent was obtained. Six healthy subjects were imaged at 1.5 Tesla and 3.0 Tesla (MAGNETOM Avanto and Verio systems; Siemens, Erlangen, Germany). The DB-bSSFP sequence used a two-shot bSSFP readout with duration of ~150 msec. The sequence was triggered to every second R-wave and a chemical shift-selective RF pulse was applied for fat suppression. Both radial and Cartesian trajectories were evaluated. Comparison was made to a standard dual-inversion turbo spin-echo pulse sequence that acquired nine echoes per readout. Image quality was evaluated by a single observer using a four-point scale (1: non-diagnostic, 2: fair, 3: good, 4: excellent) for the LV free wall, septum, RV free wall and RV trabeculae.
Results
At least four slices could be acquired per breath-hold using the DB-bSSFP technique, compared with only a single slice for DB-TSE. Mean myocardium-to-blood pool contrast-to-noise ratios at 1.5T [3.0T] were: radial DB-bSSFP, 18.2 [22.1]; Cartesian DB-bSSFP, 17.6 [26.3] (p < 0.01); DB-TSE, 14.6 [23.2] (p < 0.05). Over both magnetic field strengths, mean image quality scores for radial DB-bSSFP/Cartesian DB-bSSFP/DB-TSE were 3.8/3.8/3.2 for the LV free wall (p < 0.05), 4.0/3.8/3.5 for the septum (p < 0.05), 3.8/3.8/3.1 for the RV free wall (p < 0.01), and 3.8/3.8/2.9 for the RV trabeculae (p < 0.01). DB-bSSFP showed the least blurring from cardiac motion, particularly noticeable in the LV free wall and septum. Excellent depiction of the thin RV free wall was obtained in all subjects with DB-bSSFP. Radial DB-bSSFP permitted the use of small fields of view without wrap artifact, unlike Cartesian DB-bSSP or DB-TSE.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Ferreira Botelho, M.P., Koktzoglou, I., Li, W. et al. Dark Blood Imaging of the Heart using Dual-Inversion, Balanced Steady-State Free-Precession. J Cardiovasc Magn Reson 18 (Suppl 1), P306 (2016). https://doi.org/10.1186/1532-429X-18-S1-P306
Published:
DOI: https://doi.org/10.1186/1532-429X-18-S1-P306
Keywords
- Image Quality
- Pulse Sequence
- Magnetic Field Strength
- Free Wall
- Morphologic Imaging