Quantitative assessment of left ventricular mechanical dyssynchrony using cine cardiovascular magnetic resonance imaging: inter-study reproducibility
Journal of Cardiovascular Magnetic Resonance volume 18, Article number: P40 (2016)
Background
We aimed to determine the inter-study reproducibility of left ventricular (LV) mechanical dyssynchrony measures based on standard cardiovascular magnetic resonance (CMR) cine images.
Methods
Steady state free precession (SSFP) LV short-axis stacks as well as 2-, 3- and 4-chamber views were acquired on the same day at 9:00 (Exam A), 9:30 (Exam B) and 14:00 (Exam C) in 16 healthy volunteers. Circumferential strain systolic dyssynchrony indexes (SDI), area SDI as well as circumferential and radial uniformity ratio estimates (CURE and RURE, respectively) were derived from CMR myocardial feature tracking (CMR-FT) based on the tracking of 3 short-axis planes (basal, mid-ventricular and apical). Furthermore, 4D LV-Analysis based on short-axis stacks and all three longitudinal planes was performed to quantify 4D volume SDI. Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to study possible diurnal variation.
Results
CMR-FT derived CURE and RURE as well as 4D LV-Analysis derived volume SDI showed good inter-study reproducibility (coefficient of variation [CoV] 6.4% to 12.9%, intraclass correlation coefficient [ICC] 0.79 to 0.85). Conversely, circumferential strain and area SDI showed higher variability between the repeated measurements (CoV 24.9% to 37.5, ICC 0.67 to 0.76). Averaged CURE and RURE indexes (CURE:RUREAVG) showed the lowest inter-study variation (CoV 6.4%) with an ICC of 0.80. Dyssynchrony indexes were not measurably affected by diurnal variation between morning and afternoon scans.
Conclusions
Derivation of LV mechanical dyssynchrony measures from standard cine images is feasible using CMR-FT and 4D LV-Analysis tools. CURE:RUREAVG and 4D volume SDI showed good inter-study reproducibility. Their clinical value should next be explored in patient groups who potentially benefit from cardiac resynchronization therapy.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Kowallick, J.T., Morton, G., Lamata, P. et al. Quantitative assessment of left ventricular mechanical dyssynchrony using cine cardiovascular magnetic resonance imaging: inter-study reproducibility. J Cardiovasc Magn Reson 18 (Suppl 1), P40 (2016). https://doi.org/10.1186/1532-429X-18-S1-P40
Published:
DOI: https://doi.org/10.1186/1532-429X-18-S1-P40
Keywords
- Cardiovascular Magnetic Resonance
- Cardiac Resynchronization Therapy
- Circumferential Strain
- Mechanical Dyssynchrony
- Cardiovascular Magnetic Resonance Imaging