Utility of the signal intensity ratio of the spleen and myocardium (SMR) on T2-weighted short tau inversion recovery black-blood (T2-STIR BB) images compared to semi-quantitative analysis in patients with images with diffuse high T2 signal intensity, such as that with Takotsubo cardiomyopathy, cardiac amyloidosis, hypereosinophilic myocarditis, and apical hypertrophic cardiomyopathy

Background

T2-weighted short tau inversion recovery black-blood (T2-STIR BB) images are widely used to evaluate edematous changes in the myocardium, such as that with acute myocardial infarction, myocarditis, and several cardiomyopathies, and visual assessment has been the main method to analyze T2-STIR BB images. Though T2 mapping may provide quantitative evaluation of T2 signal intensity, T2 mapping requires additional imaging and cannot accommodate analysis of conventional T2-STIR BB images.

Methods

Among 376 consecutive patients who underwent cardiac magnetic resonance (MR) imaging examination using 1.5 Tesla MR system (Intera Achieva with 32-channel coil, Philps Medical Systems, Netherlands) between January 1, 2013 through December 31, 2014, we identified 22 cases with left ventricular ejection fraction exceeding 55% and no late gadolinium enhancement as our normal group to determine the normal range of the signal intensity ratio of the spleen and myocardium (SMR) on T2-STIR BB images. Furthermore, we evaluated the SMR of T2 -STIR BB images that showed diffuse high signal intensity, including Takotsubo cardiomyopathies (3 cases), cardiac amyloidosis (2 cases), hypereosinophilic myocarditis (one case), and apical hypertrophic cardiomyopathies (6 cases).

Results

The SMR of the normal group was 0.477 ± 0.098, so we determined the normal range of the SMR less than 0.58 (as mean + 2 standard deviations [SD]). The figure shows SMR findings of the 12 patients who demonstrated diffuse high signal intensity on T2-STIR BB images. The results of SMR that showed diffuse high signal intensity were Takotsubo cardiomyopathies; 0.68, cardiac amyloidosis; 0.77, hypereosinophilic myocarditis; 0.97, and apical hypertrophic cardiomyopathies; 0.64, respectively. Diagnostic ability of diffuse high signal intensity on T2-STIR BB was better for SMR (100%; 12/12) than visual assessment (75%; 9/12).

Conclusions

The SMR on conventional T2-STIR BB images may provide quantitative results in patients who show diffuse high signal intensity on T2-STIR BB images and offer better diagnostic ability than visual analysis of those images.

figure 1

Figure 1

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aoki, R., Nakajima, T., Nakano, Y. et al. Utility of the signal intensity ratio of the spleen and myocardium (SMR) on T2-weighted short tau inversion recovery black-blood (T2-STIR BB) images compared to semi-quantitative analysis in patients with images with diffuse high T2 signal intensity, such as that with Takotsubo cardiomyopathy, cardiac amyloidosis, hypereosinophilic myocarditis, and apical hypertrophic cardiomyopathy. J Cardiovasc Magn Reson 18 (Suppl 1), Q40 (2016). https://doi.org/10.1186/1532-429X-18-S1-Q40

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-18-S1-Q40

Keywords