Skip to main content

Table 1 Demographics and imaging parameters of the 3D-self-navigated acquisition: grouping according image quality categories

From: Single centre experience of the application of self navigated 3D whole heart cardiovascular magnetic resonance for the assessment of cardiac anatomy in congenital heart disease

  

Total cohort

Quality grade 1

Quality grade 2

Quality grade 3

Quality grade 4

Quality grade 5

P

  

N = 111

N = 1

N = 10

N = 22

N = 41

N = 37

 

Baseline characteristics

Age

years

23.4 ± 12.2

8.6

22.7 ± 14.2

23.6 ± 15.7

25.6 ± 12.7

21.4 ± 0.1

0.43

Age <16 y

N (%)

30 (27.0 %)

1 (100 %)

4 (40 %)

9 (40.9 %)

9 (22.0 %)

7 (18.9 %)

0.10

Male gender

N (%)

61 (55.0 %)

0 (0 %)

4 (40 %)

13 (59.1 %)

22 (53.7 %)

22 (59.5 %)

0.66

HR

bpm

75.4 ± 14.3

88

87.9 ± 16.3

76.3 ± 15.8

73.2 ± 12.0

73.5 ± 13.9

<0.05

SDRRa

ms

90 ± 87

48

91 ± 109

99 ± 87

108 ± 93

66 ± 72

0.31

Height

cm

160.6 ± 23.6

147

148.8 ± 33.2

152.3 ± 31.8

166.2 ± 14.4

163.0 ± 21.9

0.08

Weight

kg

58.0 ± 21.1

43

47.5 ± 24.6

53.6 ± 27.5

62.3 ± 16.8

59.1 ± 19.6

0.22

Body Mass Index

kg/m2

21.5 ± 4.9

19.9

19.44 ± 6.3

21.1 ± 6.0

22.2 ± 4.5

21.5 ± 4.1

0.59

EDVib of the systemic ventricle

ml/m2

82.4 ± 25.0

63

98.7 ± 45.9

76.1 ± 14.6

80.0 ± 18.9

84.8 ± 27.0

0.14

EF of the systemic ventricle

%

58.2 ± 8.5

60

49.3 ± 12.2

58.6 ± 10.0

59.5 ± 6.7

58.9 ± 7.0

<0.05

Baseline characteristics

Complex malformation

N (%)

49 (44.1 %)

0 (0 %)

8 (80.0 %)

11 (50.0 %)

13 (31.7 %)

17 (46.0 %)

<0.05

 - Tetralogy of Fallot

20 (18.0 %)

0

3

3

8

6

 

 - d-TGAc

13 (11.7 %)

0

2

3

3

5

 

 - Fontan circulation

3 (2.7 %)

0

0

2

0

1

 

 -Other complex

13 (11.7 %)

0

3

3

2

5

 

Non-complex malformation

N (%)

62 (55.9 %)

1 (100 %)

2 (20 %)

11 (50 %)

28 (68.3 %)

20 (54.0 %)

<0.05

 - Aortic dilatation

22 (19.8 %)

0

1

3

10

8

 

 - Coarctation aorta

7 (6.3 %)

0

0

0

5

2

 

 - After Ross operation

8 (7.2 %)

0

0

2

4

2

 

 - Septal defect

5 (4.5 %)

1

1

1

2

0

 

 - Abnormal venous return

8 (7.2 %)

0

0

1

3

4

 

 - Other non-complex

12 (10.8 %)

0

0

4

4

4

 

Corrected malformation

N (%)

76 (68.5 %)

0 (0 %)

5 (50.0 %)

14 (63.6 %)

28 (68.3 %)

29 (78.4 %)

0.21

Characteristics of the 3D sequence

Field of view

mm

205 ± 14

199

206 ± 13

204 ± 21

205 ± 11

206 ± 11

0.95

Isotropic resolution

mm

1.01 ± 0.09

0.96

1.0 ± 0.09

1.02 ± 0.10

1.01 ± 0.09

1.01 ± 0.09

0.9

Acquisition window

ms

68.2 ± 21.2

45

54 ± 25.4

67.8 ± 26.3

72.5 ± 17.5

68.3 ± 19.4

0.11

Systolic acquisition

N (%)

20 (18.0 %)

1 (100)

2 (20.0)

2 (9.1)

4 (9.8)

11 (29.7)

<0.05

Number of heart beats

N

705.3 ± 299.0

898

975 ± 495

715 ± 372

637 ± 201

698 ± 245

<0.05

Number of segments

N

22.7 ± 7.1

15

18.0 ± 8.5

22.6 ± 8.8

24.2 ± 5.8

22.8 ± 6.5

0.11

Number of scan lines

N × 1000

14.2 ± 2.1

13.4

14.3 ± 1.9

13.5 ± 2.7

14.4 ± 1.9

14.5 ± 1.9

0.48

Scan duration

min

9.5 ± 3.1

10.2

11.2 ± 3.7

9.3 ± 3.1

9.0 ± 2.4

9.6 ± 3.5

0.38

Use of contrast

N (%)

97 (87.4 %)

0 (0 %)

6 (60.0 %)

21 (95.5 %)

33 (80.5 %)

37 (100 %)

<0.001

  1. aSDRR = standard deviation of the RR interval during image acquisition
  2. bEDVi = end-diastolic volume index
  3. cd-TGA = d-transposition of the great arteries