Skip to main content

Table 3 CMR results comparing patients with acute myocarditis to controls

From: Diagnostic performance of cardiovascular magnetic resonance native T1 and T2 mapping in pediatric patients with acute myocarditis

  Control (n = 39) Acute myocarditis (n = 23) p-value
Global native T1 (ms) 989.6 ± 34.3 1097.9 ± 77.0 <0.001
Global T2 (ms) 46.7 ± 2.6 52.8 ± 4.6 <0.001
ECV (%) 23.3 ± 2.4 29.8 ± 5.1 <0.001
Segmental maximum T2 (ms) 52.4 ± 4.2 61.2 ± 7.0 <0.001
Post-Contrast Global T1M (ms) 494.3 ± 53.4 475.6 ± 80.9 0.507
  1. Mean values listed. ECV: extracellular volume