Table 4 Median strain values, measured using each technique, in patients without and with LGE and results of the Mann-Whitney test

From: Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement

  Patients without LGE Patient group with LGE p
Echo - GLS −16.0 (−19.1 to −12.7) −15.6 (−17.9 to −11.6) 0.212
FT - GLS −17.3 (−18.8 to − 13.1) − 12.5 (15.7 to −10.0) 0.003
FT - GCS − 17.8 (− 19.1 to − 13.5) − 12.0 (−14.3 to − 9.10) < 0.001
SENC - GLS −17.3 (− 20.2 to − 14.0) − 13.5 (− 14.9 to − 10.2) 0.010
SENC - GCS −14.8 (− 17.5 to − 12.9) − 12.4 (− 13.8 to − 8.90) < 0.001
  1. Data presented as median (interquartile range)