Skip to main content

Table 1 Descriptions of the CMR sequences employed in the patient study

From: Endogenous assessment of myocardial injury with single-shot model-based non-rigid motion-corrected T1 rho mapping

Sequence

T2 MAPPING

T1ρ MAPPING

LGE

Acquisition

Non-selective T2-prepared bSSFP

Non-selective T1ρ-prepared bSSFP

Non-selective IR GRE

Magnetic field, Tesla

1.5

1.5

1.5

Post-contrast

No

No

Yes

Acceleration

GRAPPA 2

GRAPPA 2

GRAPPA 2

Reconstructed resolution, mm2

1.9 × 1.9

1.4 × 1.4

1.5 × 1.5

Slice thickness, mm

8

8

4

Number of LV slices, range

3

3

11–16

ECG triggering (RR)

3

3

2

TR/TE, msec

2.5/1.1

2.7/1.2

3.9/1.7

Bandwidth, Hz/pixel

1184

1150

362

Flip angle, degrees

70

70

10

Free breathing

No

No

No

  1. bSSFP balanced steady-state free precession, ECG electrocardiogram, GRE gradient echo; LGE late gadolinium enhancement, IR inversion recovery, GRAPPA generalized autocalibrating partially parallel acquisitions, LV left ventricle, TR repetition time, TE echo time