Table 1 Patient characteristics

From: Cardiovascular magnetic resonance images with susceptibility artifacts: artificial intelligence with spatial-attention for ventricular volumes and mass assessment

 

All patients (N = 230)

Patients with CIED (n = 100)

Patients without CIED (n = 130)

p value

Age, years

56 ± 17

60 ± 17

54 ± 17

0.014

Female

68 (30%)

17 (17%)

51 (39%)

0.004

Body surface area, m2

1.9 ± 0.2

1.9 ± 0.2

1.9 ± 0.2

0.167

Cardiac rhythm

 Sinus rhythm

211 (92%)

85 (85%)

126 (97%)

0.146

 Atrial fibrillation

19 (8%)

15 (15%)

4 (3%)

Main clinical indication for CIED implantation

 AV block or symptomatic bradycardic

6 (3%)

6 (6%)

0 (0%)

 Cardiac arrest or sustained ventricular tachycardiac

76 (33%)

76 (76%)

0 (0%)

 LVEF ≤ 35%

23 (10%)

23 (23%)

0 (0%)

Main clinical indication for CMR

 Coronary artery disease

72 (31%)

25 (25%)

47 (36%)

0.515

 Ventricular arrhythmia

75 (33%)

35 (35%)

40 (31%)

 Dilated cardiomyopathy

41 (18%)

21 (21%)

20 (15%)

 Hypertrophic cardiomyopathy

18 (8%)

8 (8%)

10 (8%)

 Acute myocardial infarction

24 (10%)

11 (11%)

13 (10%)

LVEDV index (mL/m2)

90 (73–108)

101 (81–124)

85 (71–100)

< 0.001

LVESV index (mL/m2)

42 (31–59)

50 (41–86)

38 (28–50)

< 0.001

LVEF (%)

51 ± 9

45 ± 14

54 ± 11

< 0.001

RVEDV index (mL/m2)

76 (66–91)

79 (67–93)

75 (64–88)

0.203

RVESV index (mL/m2)

34 (26–42)

37 (27–49)

33 (25–40)

0.006

RVEF (%)

55 ± 9

52 ± 10

57 ± 7

< 0.001

Permanent pacemaker

16 (7%)

16 (16%)

ICDs

84 (37%)

84 (84%)

  1. Values are mean ± SD, median (interquartile range), or n (%)