Table 2 CMR findings comparing subjects with and without longer pulmonary transit time (PTT) duration

From: Association of pulmonary transit time by cardiac magnetic resonance with heart failure hospitalization in a large prospective cohort with diverse cardiac conditions

Variables

PTT < 8.2 (n = 368)

PTT ≥ 8.2 (n = 138)

p-value

LV end diastolic volume, ml/m2

86 ± 24

95 ± 38

0.0015

LV end systolic volume, ml/m2

44 ± 25

59 ± 38

< 0.0001

LV stroke volume, ml

85 ± 22

72 ± 21

< 0.0001

LV stroke volume, ml/m2

42 ± 10

36 ± 10

< 0.001

LV ejection fraction, %

51 ± 10

42 ± 15

< 0.0001

LV mass, g/m2

60 ± 16

72 ± 22

< 0.0001

RV end diastolic volume, ml/m2

72 ± 16

70 ± 21

0.3582

RV end systolic volume, ml/m2

33 ± 11

38 ± 18

0.0009

RV stroke volume, ml

77 ± 20

65 ± 19

< 0.0001

RV stroke volume, ml/m2

38 ± 9

32 ± 9

< 0.001

RV ejection fraction, %

54 ± 8

48 ± 11

< 0.0001

Left Atrial Volume, g/m2

40 ± 15

52 ± 42

< 0.001

Late gadolinium enhancement

 Infarct pattern

41 (12)

32 (23)

0.0005

 Non-infarct pattern

188 (53)

61 (45)

0.0005

 Both

5 (1)

7 (5)

0.0005

  1. Date are mean ± standard deviation or n (percentage). LV left ventricle, RV right ventricle