1071 Interobserver variability differences for cardiac MRI right ventricular (RV) volumetry and mass measures between standard and "modified" right ventricular short axis imaging in patients with chronic pulmonary insufficiency

Introduction

Standard MRI assessment of right ventricular (RV) volume and mass is based on assessment of a stack of "standard" short axis images (fig. 1) obtained with respect to the horizontal long axis of the heart. A "modified" RV short axis stack of images, based on cross-sections of the RV outflow long axis (fig. 2), has recently been demonstrated to overcome observed inaccuracies in definition of the tricuspid valve plane for the "standard" image stacks, and therefore to result in less interobserver variability and more reliable RV volume estimates in subjects with anatomically and functionally normal RVs.

figure 1

Figure 1

figure 2

Figure 2

Purpose

To determine if the "modified" RV short axis stack would decrease interobserver variability of MRI RV measurements in patients with dilated RVs due to chonic pulmonary insufficiency from previously repaired Tetraolgy of Fallot.

Methods

Prospective comparison of cardiac MRI scans of 9 adolescent/young adult patients (5 male, age range 10 to 25 years) with a diagnosis of TOF status post infantile/childhood transannular patch repair. Subjects underwent cardiac MRI for standard clinical indication on either a GE 1.5 Tesla Excite or a Siemens 3 Tesla Trio magnet. In addition to standard short axis cine SSFP stacks, a second stack of "modified" RV short axis SSFP cines was obtained perpendicular to the RV outflow long axis. RV volumetry and mass were assessed by planimetry of the endocardial and epicardial RV borders at end systole and end-diastole using Medis MASS software. RV volume and mass were measured for both sets of RV short axis stacks by 5 independent expert observers blinded to one another's data. Data were analyzed by comparison of mean standard deviations for each of the two methods.

Results

Mean interobserver standard deviations for RV end-diastolic volume were 10.3 mL (modified) vs 15.2 mL (standard) and for RV end-systolic volume were 12.8 mL (modified) vs 17.7 mL (standard). Standard deviations in RV mass measurement were 9.1 g (modified) vs 7.3 g.

Conclusion

The modified RV short axis cine stack showed improved reproducibility in estimation of RV volume measurments as compared to the standard RV short axis stack in this limited series of patients with volume overloaded RVs.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Tipton, A., Fleck, R., Crotty, E. et al. 1071 Interobserver variability differences for cardiac MRI right ventricular (RV) volumetry and mass measures between standard and "modified" right ventricular short axis imaging in patients with chronic pulmonary insufficiency. J Cardiovasc Magn Reson 10 (Suppl 1), A196 (2008). https://doi.org/10.1186/1532-429X-10-S1-A196

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-10-S1-A196

Keywords