- Poster presentation
- Open access
- Published:
Non-invasive assessment of coronary artery distensibility by 3.0 T cardiac MRI
Journal of Cardiovascular Magnetic Resonance volume 11, Article number: P38 (2009)
Introduction
Atherosclerotic changes in the coronary artery are associated with impaired coronary vessel wall distensibility [1]. Though non-invasive measures of central aortic distensibility are possible, only intravascular ultrasound (IVUS) invasive measurements of coronary distensibility have been reported until now [1, 2].
Purpose
High-field coronary magnetic resonance imaging (MRI) offers high temporal and spatial resolution, important for assessing distensibility-related changes in coronary dimensions during the cardiac cycle. We sought to test the hypothesis that coronary artery distensibility can be evaluated non-invasively with 3.0 T cardiac MRI and that distensibility differences can be detected between healthy (control group) and coronary artery disease (CAD) subjects.
Methods
Twenty healthy, adult subjects (11 male, age 19–60 years, mean 32 ± 12 years) and twelve patients with coronary catheterization documented CAD (8 male, age 50–69 years, mean 58 ± 8 years) were studied on a commercial whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). MR angiography of the right coronary artery (RCA) was performed with a navigator-gated free-breathing and ECG-triggered, T2-prepared, three-dimensional, segmented k-space, gradient-echo imaging sequence. In each subject, the proximal segment of the RCA was then imaged in cross-section using cine spiral MRI for area measurements. Imaging was performed at a constant room temperature and after at least 20 minutes of rest in the magnet. MRI parameters were: echo time (TE) = 1.5 ms, radiofrequency (RF) excitation angle = 20° and spectral spatial excitation, breath-hold duration ~14–24 sec, acquisition window = 10 ms, repetition time (TR) = 14 ms, 21 spiral interleaves, spatial resolution (acquired/reconstructed) = 0.89 × 0.89 × 8.00 mm3/0.69 × 0.69 × 8.00 mm3. Both the blood pressure and the heart rate were recorded. Images were analyzed for cross-sectional area changes using full width half maximum (Cine version 3.15.17, General Electric, Milwaukee, WI, USA), and distensibility (mmHg-1) was determined as: [(systolic lumen area – diastolic lumen area)]/(pulse pressure multiplied with the diastolic lumen area) [3]. Pulse pressure was calculated as pressure change during a cardiac cycle [2].
Results
Nineteen volunteers and eleven patients had adequate image quality for RCA area measurements (figure 1A). The mean heart-rate pressure product (heart-rate multiplied by systolic blood pressure) in healthy adults (8289 ± 1427 mmHg*beats/minute) was not significantly different from that in CAD patients (9048 ± 1878 mmHg*beats/minute), (p = 0.18). The luminal area in healthy subjects was 9.60 ± 2.02 mm2 during diastole and 12.90 ± 4.78 mm2 for CAD patients (p = 0.01). At end-systole, the luminal area in healthy subjects was 10.60 ± 2.47 mm2 and 13.55 ± 5.39 mm2 for CAD patients respectively (p = 0.049). Coronary vessel area changed significantly between systole and diastole in healthy controls (p < 0.01), but not in CAD patients (p = 0.12). In healthy subjects coronary artery distensibility (2.46 ± 2.45 mmHg-1 *103) was significantly higher than that in CAD patients (1.04 ± 0.94 mmHg-1 *103) (figure 1B) (p = 0.03). We found no significant correlation between coronary artery distensibility and coronary vessel area at either systole or diastole in healthy adults or CAD patients.
Discussion
Non-invasive assessment of coronary artery vessel wall distensibility with 3.0 T is feasible and the findings are similar to those from invasive IVUS studies [1, 2]. Coronary artery distensibility measured by 3.0 T MRI is significantly higher in healthy controls than it is in patients with documented CAD. The number of subjects needed to detect a difference is relatively small. This methodology may support the characterization of vascular anatomy and function in healthy and diseased states, as well as the response to interventions in patients with, or at increased risk for CAD.
References
Jeremias A, Spies C, Herity NA, et al: Coronary artery distensibility and compensatory vessel enlargement – a novel parameter influencing vascular remodeling?. Basic Res Cardiol. 2001, 96: 506-512. 10.1007/s003950170033.
Nakatani S, Yamagishi M, Tamai J, et al: Assessment of coronary artery distensibility by intravascular ultrasound. Application of simultaneous measurements of luminal area and pressure. Circulation. 1995, 91: 2904-2910.
Oliver JJ, Webb DJ, et al: Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler Thromb Vasc Biol. 2003, 23: 554-566. 10.1161/01.ATV.0000060460.52916.D6.
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Kelle, S., Hays, A.G., Hirsch, G.A. et al. Non-invasive assessment of coronary artery distensibility by 3.0 T cardiac MRI. J Cardiovasc Magn Reson 11 (Suppl 1), P38 (2009). https://doi.org/10.1186/1532-429X-11-S1-P38
Published:
DOI: https://doi.org/10.1186/1532-429X-11-S1-P38