Diastolic function with 3D three-directional velocity encoded MRI in patients with ischemic cardiomyopathy
Journal of Cardiovascular Magnetic Resonance volume 12, Article number: O100 (2010)
Introduction
Three-dimensional (3D) three-directional velocity-encoded (VE) MRI more accurately describes transmitral flow and regurgitation in patients with ischemic cardiomyopathy, as compared to 2D one-directional VE MRI. However, the value of diastolic function assessment from 3D VE MRI in patients with ischemic cardiomyopathy has not yet been studied.
Purpose
To compare 3D three-directional VE MRI with two-dimensional (2D) one-directional VE MRI for assessment of diastolic function in patients with ischemic cardiomyopathy.
Methods
Local medical ethics committee approval was obtained and 44 patients (31 men; mean age 60 years) gave written informed consent. Diastolic function parameters, early diastolic mitral septal velocity (E'), effective forward flow volume and regurgitation fraction were determined from transmitral flow graphs, with both VE MRI methods. Furthermore, early mitral velocity (E), E', E/A ratio and E/E' of both VE MRI methods were compared to echocardiography.
Results
3D three-directional VE MRI is statistically significantly different from 2D one-directional VE MRI for all parameters describing diastolic function, except for E/A-ratio. Furthermore, three-directional VE MRI is statistically significantly different from 2D one-directional VE MRI for assessing net forward flow (mean signed difference: -19.3 ml ± 13.9(sd); p-value < 0.01; Pearson correlation (r) 0.8) and regurgitation fraction (mean signed difference: 5% ± 7%(sd); p-value < 0.01; Pearson correlation (r) 0.5) at the mitral valve. Furthermore for both MRI-methods E, E', E/E' differed significantly from echocardiography, except for E/A-ratio. However, agreement between 3D VE MRI and echocardiography was better as compared to 2D VE MRI and echocardiography. Results for E, E', E/E' E/A-ratio for both VE MRI methods and echocardiography are described in table 1.
Conclusion
3D three-directional VE MRI is more accurate in transmitral flow assessment than 2D one-directional VE MRI, and therefore we assume that diastolic function parameters are more accurately assessed with 3D three-directional VE MRI. Also, 3D three-directional VE MRI shows better agreement with echocardiography.
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Brandts, A., Bertini, M., van Dijk, E. et al. Diastolic function with 3D three-directional velocity encoded MRI in patients with ischemic cardiomyopathy. J Cardiovasc Magn Reson 12 (Suppl 1), O100 (2010). https://doi.org/10.1186/1532-429X-12-S1-O100
Published:
DOI: https://doi.org/10.1186/1532-429X-12-S1-O100
Keywords
- Mitral Valve
- Diastolic Function
- Ethic Committee Approval
- Ischemic Cardiomyopathy
- Function Assessment