- Oral presentation
- Open access
- Published:
Classification of myofibers using statistics of the helix angle: a novel approach to characterize the structure of the human heart
Journal of Cardiovascular Magnetic Resonance volume 13, Article number: O44 (2011)
Purpose
To characterize the microstructure of human/mammalian hearts using a statistical definition of fiber helix angle in the myocardial continuum.
Introduction
The integration of primary eigenvectors in a diffusion field yields continuous tracts, to which it is useful to assign a single helix angle. However, the optimal approach to derive the helix angle of a continuous tract in the myocardium remains unclear. Strategies used in the brain and in prior tractographic studies in the heart (Circ Cardiovasc Imaging. 2009; 2(3): 206-12) may not be optimal for the myocardial continuum.
Methods
Excised human, sheep and rat hearts (n=12) were studied. Diffusion tensor MRI (DT-MRI) of the human and sheep hearts was performed at 3T using 6 gradient-encoding directions; a b-value of 2000s/mm2; voxel-size=2x2x2mm3; TR/TE=8430/96ms; and 24 averages. DT-MRI of the rat hearts was performed at 4.7T using a b-value of 2000 s/mm2 and spatial resolution of 0.4x0.4x0.4 mm3. Fiber tracking was performed with a fourth-order Runge-Kutta approach. The helix angle assigned to each tract was defined in three ways: 1) Each voxel in the tract had its own (original) helix angle defined by its primary eigenvector, 2) the entire tract was classified by its median helix angle, or 3) by its mean helix angle.
Results
The impact of the helix angle classification scheme was dependent on fiber length and the noise in the dataset. Helix angles were similar with all approaches when fiber length was limited to the ROI (Figure 1A-C). Significant differences, however, were seen when fiber length was equal to half the circumference of the left ventricle (πR) (Figure 1D-F). The median classification excluded noisy/outlier voxels and produced a helix angle pattern with greater angular resolution than the mean classification scheme, which is affected by outlier voxels. The greater angular resolution produced by the median approach can be seen in the epicardial (red) fibers in Figure 1D-F and the histograms in Figure 2D-F. Far greater differences between the median and mean approaches are seen with noisier datasets. Fiber classification by local/original helix angle revealed that the helix angle along myofibers tended to be lower (more circumferential) at the apex and base than at the midventricular level (Figure 1D).
Conclusions
The helix angle along a given myofiber is not constant and is highest at the midventricular level. The classification of myofibers based on their median helix angles strikes the optimal balance between clarity and preserved angular resolution.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Mekkaoui, C., Huang, S., Dai, G. et al. Classification of myofibers using statistics of the helix angle: a novel approach to characterize the structure of the human heart. J Cardiovasc Magn Reson 13 (Suppl 1), O44 (2011). https://doi.org/10.1186/1532-429X-13-S1-O44
Published:
DOI: https://doi.org/10.1186/1532-429X-13-S1-O44