Temporal changes in diastolic function measured by volumetric CMR after ST Elevation Myocardial infarction
Journal of Cardiovascular Magnetic Resonance volume 13, Article number: P138 (2011)
Objective
We aim to evaluate changes in diastolic function after ST elevation myocardial infarction (STEMI) using volumetric cardiac magnetic resonance imaging (CMR), as well as the relation of diastolic parameters to baseline variables including peak troponin-I and baseline left ventricular ejection fraction (LVEF).
Background
Diastolic dysfunction is one of the earliest manifestations of cardiac ischemia. However, the response to reperfusion of diastolic filling parameters in patients with STEMI undergoing primary percutaneous coronary intervention (PCI) is not well elucidated. Using volumetric analysis we aimed to define the temporal change in diastolic function after primary PCI.
Method
23 patients with STEMI undergoing primary PCI were prospectively enrolled and sequential CMR imaging was performed within 96 hours of admission and at 1 month follow up. LV volumetric quantification was performed (QMass MR, Medis, Leiden, The Netherlands) with manual planimetry of the endocardial contours in all temporal phases of the contiguous short-axis slices. Systolic parameters were obtained. Diastolic CMR parameters were derived including peak filling rate (PFR) and its index normalized to end diastolic volume (NPFR), time to peak filling rate (TPFR), diastolic volume recovery (DVR80): proportion of diastole required for recovery of 80 percentage of stroke volume as well as the ratio of the biphasic early (E) and late (A) filling profiles (E/A ratio). The change in those parameters was then correlated to peak troponin-I and baseline LVEF.
Results
At one month follow-up LVEF improved from 49% (interquartile range (38-61) at baseline to 57% (49-62), p=0.04. There were no significant changes in LV volumes; LV end diastolic volume changed from 194.5ml ( 152.9-237.0) to 192ml (152.5-221.7), p=0.14) and LV end systolic volume from 100ml (65.0-125.8) to 87.71ml (52.8-96.0), p=0.08. The changes in the diastolic parameters are depicted in table 1. PFR, TPFR and NPFR did not change significantly however E/A increased from 1.06 to 1.63 while DVR80 decreased from 86.1% to 83.2%. Figure 1.

The change in DVR80 and E/A ratio was not correlated with peak troponin, baseline LVEF, or baseline LV volumes.
Conclusion
Improvement in LVEF with reperfusion did not translate to improvement in PFR, NPFR and TPFR which have been traditionally used as indices of diastolic function. On the other hand, significant changes were seen in DVR80 and E/A ratio. These parameters may serve as targets from future investigation in the effect of revascularization on myocardial function.
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Ghimire, G., Shrestha, J., Gonzalez, M.A. et al. Temporal changes in diastolic function measured by volumetric CMR after ST Elevation Myocardial infarction. J Cardiovasc Magn Reson 13 (Suppl 1), P138 (2011). https://doi.org/10.1186/1532-429X-13-S1-P138
Published:
DOI: https://doi.org/10.1186/1532-429X-13-S1-P138
Keywords
- Leave Ventricular Ejection Fraction
- Cardiac Magnetic Resonance
- Diastolic Function
- Cardiac Magnetic Resonance Imaging
- Primary Percutaneous Coronary Intervention