- Poster presentation
- Open access
- Published:
Detection and correction of regional shape bias arising from imaging protocol: differences between GRE and SSFP
Journal of Cardiovascular Magnetic Resonance volume 14, Article number: P270 (2012)
Summary
We present a methodology to detect and correct shape bias arising from imaging protocol in an atlas of the left ventricle. We show how it can be used to correct the differences between GRE and SSFP shapes and volumes.
Background
It is well established that different imaging protocols lead to different clinical parameters, for example gradient recalled echo (GRE) and steady state free precession (SSFP) protocols lead to different cardiac mass and volumes[1]. However, it is not known whether these differences are local or global in nature. Correction of local biases in heart shape is required for patient follow-up and meta-analyses of clinical trials which acquire data using different protocols.
For example, the Cardiac Atlas Project (CAP)[2]includes GRE images of asymptomatic volunteers from the MESA study[3]and patients with myocardial infarction imaged by SSFP from the DETERMINE study [4].By computing a shape mapping from one protocol to another, we can establish a bias-free comparison between these two populations.
Methods
Finite element shape models of the left ventricle (LV) were customized to 46 normal volunteers imaged by both GRE and SSFP and a multi-dimensional statistical transform was developed to correct the systematic bias between the protocols. Given that in our method there is no a priori guarantee that the mapping of local parameters will also obey the previously reported differences in terms of mass and volumes, errors were examined using both local shape and global volumetric measures.
Results
There was a systematic local difference between GRE and SSFP around the apex and papillary muscles at ED, and also around the base at ES (Fig. 1) which is probably due to the flow induced variation in blood-myocardial contrast in GRE imaging. The bias was corrected locally and the mapping also provided a global correction for volume (Table 1). Further, cross-validation experiments showed that this methodology only required ~25 cases with both modalities to determine the transformation to robustly convert between scanning techniques.
This methodology can also be successfully applied to other types of bias, for instance, that of different analysts or, between data processed by different laboratories.
Conclusions
GRE and SSFP cardiac imaging protocols give rise to regional differences in LV geometry. We have established a generalisable framework which removes these biases and also corrects for mass and volumes.
Funding
NIH - National Heart, Lung and Blood Institute (Award Number R01HL087773).
References
Malayeri AA et al: Journal of Magnetic Resonance Imaging. 2008, 28: 60-
Fonseca , Carissa G et al: Bioinformatics (Oxford Journals). 2011, doi: 10.1093/bioinformatics/btr360
Bild DE et al: American Journal of Epidemiology. 2002, 156: 871-
Kadish AH et al: Journal of Cardiovascular Electrophysiology. 2009, 20: 982-987.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Medrano-Gracia, P., Bluemke, D.A., Cowan, B.R. et al. Detection and correction of regional shape bias arising from imaging protocol: differences between GRE and SSFP. J Cardiovasc Magn Reson 14 (Suppl 1), P270 (2012). https://doi.org/10.1186/1532-429X-14-S1-P270
Published:
DOI: https://doi.org/10.1186/1532-429X-14-S1-P270