Quantitative assessment of myocardial motion from displacement measurements derived from velocity encoded MRI
Journal of Cardiovascular Magnetic Resonance volume 14, Article number: W20 (2012)
Summary
It is objective of this study to investigate the potential of velocity encoded MRI (TPM) to derive quantitative parameters based on local displacement information for the automatic assessment of mechanical asynchrony in CRT patients.
Background
About 30% of patients treated with cardiac resynchronization therapy (CRT) do not benefit. Several MRI derived parameters have been published for quantification of mechanical asynchrony. Most parameters are based on tagging techniques. Evaluation of the tagging information is often cumbersome due to fading of the tag pattern (SPAMM) or low SNR (CSPAMM) especially during diastole.
Methods
12 volunteers (30±8 years) and 3 patients (41±11 years) were investigated at a 3T whole body MR scanner (Achieva, Philips) with a 32 channel coil. The patients suffer from DCM, asynchrony and/or LBBB. A velocity encoded navigated segmented gradient echo sequence was applied in the apical, equatorial and basal slice. Acquisition parameters: FOV=3402mm2, in-plane res. =2.52mm2, slice thickness =8mm, TR/TE=6.3ms/4.6ms, α=15°, 3 k-lines per segment, VENC=30cm/s,scan duration =5.51 min., black blood imaging with alternating presaturation pulses[1], SENSE=2 and 32 cardiac phases for 60 bpm.
Displacement and strain were calculated from the TPM data. Quantitative parameters derived included: circumferential and radial temporal uniformity of strain (TUS)[2–5], regional variance of strain (RVS) and regional variance of principle strain(RVVPS)[2], standard deviation of onset and peak time (SD(Tonset),SD(Tpeak))[6], coefficient of variance (CV) and difference between septal and lateral peak circumferential strain (DiffSLpeakCS)[6, 7], the absolute values of the OS and PS delay vector between septal-lateral (SL), inferior-anterior (IA) and apical-basal (AB) wall[8, 9] and the base apex rotation coefficient (BARC)[10].
Results
Table 1 summarizes the quantified parameters for the volunteer and patient group. TUSc, SD(Tonset), the coefficient of variation, all OS delay values and the SL and IA PS delay values and BARC are not within the standard deviation of the respected volunteer data. Figure 1 shows the displacement of apical and basal slices exemplarily for one volunteer and one patient with proven asynchrony, with a clear loss of twisting motion.
Conclusions
All parameters for asynchrony quantification based on tagging published earlier can also be derived from TPM data and similar differences between volunteers and patients as known from tagging are observed. Since TPM data provide higher spatial resolution and the evaluation appears less error prone than the tagging analysis, TPM may become a helpful adjunct for automatic assessment of mechanical asynchrony.
Funding
AL and VR have a research agreement with Philips Medical, PE is employed by Philips Healthcare.
References
Lutz : MAGMA. 2011, 24: 127-35.
Helm : CIRCULATION. 2005, 111: 2760-2767.
Byrne : J AM COLL CARDIOL. 2007, 50: 1484-1490.
Bertola : J AM SOC ECHOCARDIOG. 2009, 22: 665-671.
Bilchick : JACC Cardiovasc Imaging. 2008, 1: 561-568.
Nelson : Circulation. 2000, 101: 2703-2709.
Rüssel : JMRI. 2007, 26: 1452-1460.
Zwanenburg : Am J Physiol Heart Circ Physiol. 2004, 286: H1872-1880.
Zwanenburg : J AM COLL CARDIOL. 2005, 46: 2215-2222.
Rüssel : J CARD FAIL. 2009, 15: 717-725.
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Lutz, A., Paul, J., Etyngier, P. et al. Quantitative assessment of myocardial motion from displacement measurements derived from velocity encoded MRI. J Cardiovasc Magn Reson 14 (Suppl 1), W20 (2012). https://doi.org/10.1186/1532-429X-14-S1-W20
Published:
DOI: https://doi.org/10.1186/1532-429X-14-S1-W20