Turbulent kinetic energy from CMR identifies disturbed diastolic flow in myopathic left ventricles
Journal of Cardiovascular Magnetic Resonance volume 15, Article number: E114 (2013)
Background
Turbulent blood flow is a cause of energy loss in the cardiovascular system, and can thus be seen as a measure of flow inefficiency. Novel 4D flow CMR methods permit estimation of intracardiac turbulent kinetic energy (TKE). On the basis of the Reynolds number, one might expect that larger left ventricular (LV) size would promote higher TKE values, and thus lower flow efficiency. In this study, we hypothesized that the TKE of diastolic inflow would be larger in the dilated LVs of heart failure patients compared to normal LVs.
Methods
CMR 4D flow and morphological data were acquired in 9 patients with dilated cardiomyopathy (DCM) (51±13 years old [mean±SD], 5 females) and 11 healthy subjects (Healthy) (43±18 years old., 5 females). The LV was segmented (http://medviso.com/products/segment/) at each diastolic time frame. Total TKE was calculated (Dyverfeldt et al., JMRI 2011) within the segmented LV at each diastolic time frame (Figure 1). At early and late diastolic filling, the peak total TKE was compared with transmitral velocity as well as anterior-posterior dimensions of the basal LV and the mitral annulus, respectively (Table 1).
Results
LV end-diastolic diameter and LV ejection fraction were higher and lower, respectively, in DCM compared to Healthy (61±5 vs 47±4 mm, and 41±5 vs 62±3 %, both p<0.001). In the majority of subjects, peaks in total TKE could be observed at early and late diastolic filling. Peak total TKE at late filling was higher in DCM compared to Healthy (2.8±1.7 vs 1.2±0.7 mJ, p=0.01); there was no difference in peak total TKE at early filling between the groups (NS). At early filling, peak total TKE related moderately to mitral annular dimension and transmitral peak velocity (Table 1). At late filling, peak total TKE related moderately to LV dimension (Table 1).
Conclusions
For both normal and DCM LVs, during early filling TKE relates to inflow characteristics of annular dimensions and mitral inflow velocity, but not to LV size. TKE values in normal LVs are highest during early diastole, and are lower when the LV is at its largest size. In contrast, in DCM LVs TKE increases as the LV size increases, and exceeds values in normal LVs. Energy loss due to late diastolic TKE may reflect inefficient flow in dilated and hypocontractile LVs of heart failure patients.
Funding
This study was funded by the Swedish Research Council and the Swedish Heart-Lung foundation.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Zajac, J., Eriksson, J., Dyverfeldt, P. et al. Turbulent kinetic energy from CMR identifies disturbed diastolic flow in myopathic left ventricles. J Cardiovasc Magn Reson 15 (Suppl 1), E114 (2013). https://doi.org/10.1186/1532-429X-15-S1-E114
Published:
DOI: https://doi.org/10.1186/1532-429X-15-S1-E114
Keywords
- Turbulent Kinetic Energy
- Heart Failure Patient
- Early Filling
- Left Ventricular Size
- Late Filling