Skip to main content

Table 1 Strain values and times to peak in Ebstein's anomaly and normal controls.

From: Quantification of intra and inter-ventricular dyssynchrony in Ebstein's anomaly using cardiovascular magnetic resonance myocardial feature tracking

Mean ± Standard Deviation LV RV
  GLS [%] TPK GLS [ms] GLS [%] TPK GLS [ms]
Ebstein's Anomaly -17.2 ± 4.3 330 ± 58 -15.7 ± 5.2 338 ± 78
Volunteers -17.7 ± 4.3 336 ± 36 -21.1 ± 2.9 338 ± 26