- Poster presentation
- Open Access
- Published:
Reduced fetal cerebral oxygen consumption is associated with abnormal white matter in newborns with congenital heart disease
Journal of Cardiovascular Magnetic Resonance volume 17, Article number: P201 (2015)
Background
Congenital heart disease (CHD) is associated with brain dysmaturation, increased risk of perioperative white matter (WM) injury and neurodevelopmental delay (1). Fetal Doppler studies have shown altered cerebrovascular flow dynamics in CHD, suggesting ‘brain-sparing physiology'. We sought to determine whether postnatal cerebral WM microstructural abnormality relates to abnormal fetal hemodynamics.
Methods
This prospective IRB approved study included 15 fetuses with CHD and 25 normal fetuses at 36 gestational weeks, who underwent phase-contrast MRI using metric optimized gating and T2-mapping for MR oximetry in the major vessels, according to our previously published technique (2). Neonatal MRI was performed at 5 days (SD 5 days) including diffusion tensor imaging and axial T2W-FSE. Apparent diffusion coefficient (ADC) values were measured in the centrum semiovale (CSO), frontal and parietal deep WM, and mean cerebral WM-ADC was calculated. Visual scoring of WM was performed using a 0 - 6 scale (number of T2-hyperintense regions).
Results
Ascending aortic oxygen saturation (AAoSO2), VO2 and CVO2 were significantly lower in the CHD group (49% vs. 58%, p = 0.02; 5.03 ml/min/kg vs. 7.12 ml/min/kg, p= 0.02 and 2.98 ml/min/kg vs. 4.23 ml/min/kg, p=0.03, respectively). Although mean SVC flow (a surrogate for cerebral flow) was higher in CHD fetuses, the difference was not statistically significant. However, there was a moderately strong correlation between SVC flow and mean cerebral WM-ADC (Pearson's r =0.38, p= 0.012) (Figure 1a). ADC was higher in CHD neonates in the frontal WM (by 6.9 %, p= 0.008), parietal WM (by 5.9 %, p= 0.02), and CSO (by 2.3 %, not statistically significant). Visual T2-score was significantly higher in CHD neonates (3.08 vs. 1.16, p=0.002), with a negative correlation with AAoSO2 (r = -0.33, p= 0.04) and VO2 (r= -0.47, p= 0.005) (Figure 1b and 1c).
Relations between fetal hemodynamics and neonatal white matter (WM) changes in congenital heart disease. A) Positive correlation between fetal SVC flow and neonatal WM apparent diffusion coefficient. B) Negative correlation between fetal ascending aortic oxygen saturation and neonatal WM T2-score. C) Negative correlation between fetal oxygen consumption and neonatal WM T2-score. Pearson's r and p-values are in accompanying boxes.
Conclusions
We conclude that neonatal WM abnormalities in CHD are due to reduced fetal oxygenation. The correlation between more severe WM abnormality and elevated SVC flow, a known marker of acute fetal hypoxia (the "brain sparing" response) is further evidence that WM changes are driven by reduced cerebral oxygenation in utero.
Funding
This study was funded through an operating grant from the CIHR and a PHN New Scholar Award (NIH).
References
Dimitropoulos A, et al: Brain injury and development in newborns with critical congenital heart disease. Neurology. 2013, 81 (3): 241-8. 10.1212/WNL.0b013e31829bfdcf.
Sun L, et al: Comprehensive human fetal hemodynamic assessment by phase contrast MRI and MR oximetry. ISMRM. 2014, Milan, Abstract
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Muthusami, P., Madathil, S., Blaser, S. et al. Reduced fetal cerebral oxygen consumption is associated with abnormal white matter in newborns with congenital heart disease. J Cardiovasc Magn Reson 17 (Suppl 1), P201 (2015). https://doi.org/10.1186/1532-429X-17-S1-P201
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-P201
Keywords
- White Matter
- Apparent Diffusion Coefficient
- Congenital Heart Disease
- Diffusion Tensor Imaging
- White Matter Abnormality