Indirect quantification of mitral regurgitation using cardiovascular magnetic resonance: A comparison of techniques

Background

Indirect quantification of mitral regurgitation (MR) by cardiovascular magnetic resonance (CMR), currently used as a second-line diagnostic tool after echocardiography, can be achieved by three methods. Each method has its advantages and disadvantages due to the limitations of the underlying techniques used to determine ventricular volumes and/or flow information. The aim of the study was to compare all three indirect CMR methods to determine their agreement in grading MR severity.

Methods

This prospective study comprised 29 patients (mean age 60 ± 11 (standard deviation (SD)), 97% males) with severe chronic MR who underwent an echocardiographic and CMR exam prior to surgery. Steady-state free precession sequences were used to obtain a short-axis data set to evaluate left and right ventricular stroke volumes (LV/RVSV) and phase-contrast velocity sequences were applied to obtain aortic forward flow (AoFF) and mitral inflow (MiIF). The mitral regurgitant volume (MRV) was determined by the ‘standard' (MRV = LVSV - AoFF), ‘volumetric' (can only be used in the absence of multivalvular disease and intra-cardiac shunt; MRV = LVSV - RVSV) and ‘flow' method (MRV = MiIF - AoFF). The mitral regurgitant fraction (MRF) was calculated as follows: MRV/LVSV x 100% (‘standard'/‘volumetric' method) or MRV/MiIF x 100% (‘flow' method). Agreement between the techniques was evaluated using the Bland-Altman method.

Results

The main indication for surgery was symptomatic MR (n=27) or severe LV dilatation. All patients had a dilated LV (mean end-diastolic volume 281 ± 49 ml) with preserved systolic function (mean ejection fraction 64 ± 5 %) secondary to degenerative mitral valve disease with prolapse (Carpentier type II). Seven patients had ≥ mild pulmonary and/or tricuspid regurgitation according to echocardiography and were therefore excluded from the ‘volumetric' method. All three techniques determined an overall significant different MRV and MRF (Table 1). There was good to moderate agreement between the methods despite wide 95% limits of agreement (Table 2). The MRV was below the guideline cut-off value of 60 ml in 0%, 14% and 17% of the cases, and the MRF was below the guideline cut-off value of 50% in 24%, 68% and 52% of the cases, using the ‘standard', ‘volumetric' and ‘flow' method respectively.

Table 1 Comparison of the indirect CMR methods for MR quantification.
Table 2 Bland-Altman analysis of the indirect CMR methods for MR quantification.

Conclusions

In the present study, we demonstrate that the three indirect CMR methods for MR quantification show good to moderate agreement although each technique determines an overall significant different MRV and MRF. In clinical practice, the choice of method might therefore affect the grading of MR severity and thereby the timing of surgery. Due to the lack of a true "gold standard", it is not possible to say which method quantifies MR severity with the highest accuracy and reliability.

Funding

This study was funded by a project grant from the Health & Medical Care Committee of the Regional Executive Board, Västra Götaland Region, Sweden.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Polte, C.L., Bech-Hanssen, O., Johnsson, Å.A. et al. Indirect quantification of mitral regurgitation using cardiovascular magnetic resonance: A comparison of techniques. J Cardiovasc Magn Reson 17 (Suppl 1), P361 (2015). https://doi.org/10.1186/1532-429X-17-S1-P361

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-17-S1-P361

Keywords