Background
Coronary arterial imaging in pediatric patients is challenging for multiple reasons, including higher heart rates and smaller vessel sizes. 3D respiratory navigator inversion recovery gradient echo (NAV IR GRE) imaging after administration of a blood pool contrast agent has shown advantages compared to 3D T2 prepared bSSFP imaging. Both techniques, however, provide unreliable acquisition timing since respiratory navigation efficiency varies based on patient conditions. Self-navigated (SN) whole heart imaging using a T2 prepared bSSFP readout, with tracking of the intracardiac blood pool rather than the diaphragm resulting in 100% efficient data acquisition, has been previously introduced. This technique, however, has not been applied using an IR preparation and GRE readout (SN IR GRE). We therefore sought to apply the SN IR GRE methodology in pediatric patients.
Methods
A previously described prototype 3D radial phyllotaxis SN pulse sequence was converted to perform an IR preparation pulse and GRE based readout. A series of iterative experiments was performed to optimize flip angle, bandwidth and inversion time after administration of gadofosveset trisodium. Once optimal parameters were determined, 10 patients underwent both respiratory navigated and self-navigated 3D imaging on a 1.5T scanner (Siemens MAGNETOM Aera). Images were assessed for coronary artery clarity, including quantitative assessment of SNR and CNR, vessel sharpness, and visualized length using the "Soap-Bubble" tool.
Results
SN IR GRE image quality was optimized with flip angle = 15°, bandwidth = 1000 Hz/Px, and inversion time = 290 ms. The median age of the patient cohort was 15.1 years (range 7.1 - 17.7), with an average heart rate of 77±15 bpm. Diagnoses included Tetralogy of Fallot (5), coronary artery anomaly (2), bicuspid aortic valve (2), and d-transposition of the great arteries (1). Acquisition duration for the SN IR GRE was extremely predictable, with an inverse linear relationship with heart rate. Image quality was excellent for all patients with both methodologies (Figure 1), with diagnostic visualization of the coronary origins and proximal courses. On side-by-side qualitative comparison, the SN IR GRE was superior in 4, inferior in 4, and equivalent in 2 patients. Quantitative assessment of vessel sharpness and distance visualized are shown in Table 1. SNR and CNR were higher using the NAV IR GRE (p<0.01), but vessel sharpness and visualized length were not statistically different for the LCA and RCA.
Conclusions
Self-Navigated IR GRE acquisitions are feasible in pediatric patients, with predictable acquisition times. Diagnostic quality is excellent, and though SNR and CNR are higher with NAV IR GRE, vessel sharpness and visualized length were not different for the coronary arteries.
Funding
None.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Slesnick, T., McNeal, G.R., Tandon, A. et al. 3D contrast enhanced self navigated inversion recovery gradient echo coronary imaging in pediatric patients. J Cardiovasc Magn Reson 17 (Suppl 1), Q98 (2015). https://doi.org/10.1186/1532-429X-17-S1-Q98
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-Q98
Keywords
- Bicuspid Aortic Valve
- Coronary Artery Anomaly
- Blood Pool Contrast Agent
- Gadofosveset Trisodium
- Vessel Sharpness