Steps towards automated image segmentation as part of a 3D printing pipeline in congenital heart disease
Journal of Cardiovascular Magnetic Resonance volume 18, Article number: P190 (2016)
Background
The combination of 3D printing with CMR images has the potential to allow full, tactile appreciation of the complex of structures that make up a congenital heart abnormality. However, the use of 3D printing is mostly limited to larger teaching hospitals and research centres. Others working in this area have suggested that the technical and medical expertise necessitated by manual image segmentation procedures preclude the translation of this technology into mainstream care. In particular, the laborious nature of existing methods demand an unrealistic amount of the clinician's time to achieve a full segmentation of the relevant structures.
Methods
A systematic review of the literature, including 124 unique reports on 3D printed models of cardiac anatomy, showed that the majority of reports relied on predominantly manual methods and only considered a single image data set.
Based on these observations, a novel image segmentation pipeline has been developed that takes advantage of the complementary information contained within time-resolved angiography (4D MRA) and morphology (3D SSFP) acquisitions (see Figure 1).
The performance of the pipeline was assessed in 6 cases of duct dependent pulmonary atresia with ventricular septal defect. It was compared with manual segmentation alone, both for geometrical consistency and the operator time needed to complete segmentation.
Results
Automated segmentation delivered a mean Dice Similarity Coefficient (DSC) of 0.87 indicating excellent agreement between novel and manual pipelines. The median operator times for the manual and novel segmentation pipelines were 2 h 0 m (IQR = 2 h 8 m - 1 h 27 m), and 31 m (IQR = 41 m - 24 m), respectively. The median time saving associated with the novel pipeline of 1 h 23 m (IQR = 1 h 35 m - 1 h 1 m) was found to be statistically significant (p = 0.028) using the related samples Wilcoxon signed ranks test.
Conclusions
The proposed pipeline has demonstrated that information from multi-modal CMR acquisitions can be favourably combined to automate aspects of image segmentation, reducing operator time. The combination of MRA with morphology data is just one example a set of scans that provide complementary information. It is thought that by incorporating further data from the array of images acquired as part of a typical CMR protocol, the segmentation of cardiac structures could become an increasingly automated procedure. Future developments in this area may foster the wider application of 3D printing in the routine care of those with congenital heart disease.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Byrne, N., Forte, MN.V., Narayan, S. et al. Steps towards automated image segmentation as part of a 3D printing pipeline in congenital heart disease. J Cardiovasc Magn Reson 18 (Suppl 1), P190 (2016). https://doi.org/10.1186/1532-429X-18-S1-P190
Published:
DOI: https://doi.org/10.1186/1532-429X-18-S1-P190