Diagnostic accuracy of Dixon water fat suppression coronary artery magnetic resonance angiography at 3.0 Tesla

Background

X-Ray coronary angiography (XRA) remains the gold standard for assessment of coronary artery disease (CAD) although has associated clinical risk and financial cost. Coronary artery magnetic resonance angiography (CMRA) requires effective fat suppression as the epicardial vessels are embedded within fat. The aim of this study was to assess the diagnostic performance of non-contrast enhanced whole-heart two-point Dixon multi-echo fat-water separation coronary angiography at 3T in patients with suspected CAD.

Methods

Prospective, consecutive patients (n = 45) with angina underwent both XRA and free breathing Dixon 3D whole-heart CMRA within 60 days (3T Philips Achieva TX). Imaging parameters included field-of-view = 300 × 300 × 100 mm3, resolution = 1.2 × 1.2 × 1.2 mm3, TR/TE1/TE2 = 4.0/1.36/2.4 ms, α = 20°, and SENSE = 2 with a nominal scan time of 7:03 mins assuming a heart rate of 60 bpm. Navigator gating window was 5 mm with mid-diastolic image acquisition. A double-blind analysis of the two diagnostic procedures was performed at two independent centres. CMRA image quality score, vessel sharpness and length were measured and percentage diameter stenosis graded visually on a 4-point scale (4 = best). XRA stenoses were measured quantitatively (QCA).

Results

CMRA and XRA were completed in 42(93%) patients, with a prevalence of XRA defined significant CAD of 52%. 199 of 210 (95%) proximal and mid-vessel segments were assessable with a mean image quality score of 2.7 ± 1.2, vessel sharpness 44 ± 7% and length 56 ± 23 mm. The sensitivity for the detection of CAD was 90.9% (95%CI:70.8-98.9%), specificity 75.0%(50.9-91.3), positive predictive value 80.0%(59.3-93.2), negative predictive value 88.2%(63.6-98.5), accuracy 83.3%(72.1-94.6), Likelihood Ratio Positive (LR+) 3.63(1.68-7.86) and Likelihood Ratio Positive (LR-) 0.12(0.03-0.47)(Table 1).

Table 1 Diagnostic accuracy of mDIXON coronary MRA for the detection of significant coronary artery disease compared to the reference test X-ray angiography.

Conclusions

Two-point Dixon CMRA at 3T detects XRA defined coronary artery disease with a sensitivity of 90.9% and specificity of 75.0%. The Dixon technique is a useful rule-out test for significant CAD with a negative predictive value of 88.2% and LR- of 0.12.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ripley, D.P., Nezafat, M., Foley, J.R. et al. Diagnostic accuracy of Dixon water fat suppression coronary artery magnetic resonance angiography at 3.0 Tesla. J Cardiovasc Magn Reson 18 (Suppl 1), Q11 (2016). https://doi.org/10.1186/1532-429X-18-S1-Q11

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-18-S1-Q11

Keywords