Using CMR to improve the diagnostic accuracy of the ECG for the detection of left ventricular hypertrophy; production of a simple adjustment for body mass index
https://doi.org/10.1186/1532-429X-18-S1-Q35
© Rider et al. 2016
- Published: 27 January 2016
Keywords
- Cardiac Magnetic Resonance
- Left Ventricular Hypertrophy
- Validation Cohort
- Adjustment Factor
- Initial Cohort
Background
The electrocardiogram (ECG) is the most widely used screening tool to detect left ventricular hypertrophy (LVH). However, current diagnostic criteria are highly insensitive, particularly in modern society with increasing prevalence of obesity. We aimed to use cardiac magnetic resonance (CMR) imaging to assess anatomical LV axis (frontal and lateral axis) and LV mass across a wide range of different body sizes, to generate a simple and clinically applicable adjustment factor that could be applied to increase the sensitivity of the most commonly used diagnostic criteria.
Methods
A single centre, retrospective study of 1295 participants. An initial cohort (n = 821, ♂n = 450, ♀n = 371, aged 19-87 years) with a wide range of body mass index (BMI, 17.1-53.3 kg/m2) underwent CMR evaluation (1.5T) to determine anatomical LV axis and LV mass, as well as a standard 12-lead surface ECG. The anatomical LV axis was defined as the plane between the centre of the mitral valve and the LV apex using multi-planar reconstruction of thoracic Half fourier Acquisition Single shot Turbo spin Echo (HASTE) images within cmr42 ©. LVH was defined as >2SD higher than the mean of the normal Oxfordshire population from which the study sample was taken (>165 g in males, >150 g in females). The effect of BMI and LV axis on Sokolow-Lyon index (S in V1 + R in V5/V6 ≥ 35 mm) and Cornell criteria (S in V3 + R in aVL >28 mm (♂) or > 20 mm (♀)) were then calculated and an adjustment factor generated. A second validation cohort (n = 474, BMI 15.9-63.2 kg/m2) underwent CMR evaluation (1.5T) to determine LV mass, and standard 12-lead surface ECG. Sensitivity and specificity for the ECG detection of CMR derived LVH was then determined for the study groups with and without adjustment.
Results
Improving the diagnostic accuracy of the surface ECG.
Conclusions
By using CMR to assess LV mass and anatomical axis deviation we have generated a simple BMI based clinically relevant adjustment factor for the surface ECG. Adjusting the Sokolow-Lyon index for BMI (overweight +4 mm, obesity +8 mm) dramatically improves the diagnostic accuracy for detecting LVH. As the ECG, worldwide, remains the most widely used screening tool for LVH, implementing these findings should translate into significant clinical benefit.
Authors’ Affiliations
Copyright
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.