Skip to main content

Table 2 Summary of average mean and standard deviation of the signal and the signal to noise ratio (SNR) for normal and edematous myocardium

From: T2STIR preparation for single-shot cardiovascular magnetic resonance myocardial edema imaging

 

T1 map

T2 map

T2p-bSSFP

T2STIR-bSSFP

Myocardial signal

1218 ± 76 ms

43 ± 3 ms

90 ± 11

37 ± 9

Edema

1493 ± 48 ms

57 ± 4 ms

124 ± 16

86 ± 14

SNR of normal myocardium

34.7 ± 8.2

16.3 ± 5.4

9.9 ± 4.2

5.0 ± 1.5

SNR of edema

41.7 ± 10.7

21.9 ± 8.1

12.8 ± 4.8

9.9 ± 3.1