Skip to main content

Correction to: Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel Compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography

The Original Article was published on 23 January 2020

Correction to: J Cardiovasc Magn Reson

https://doi.org/10.1186/s12968-019-0591-y

The original publication of this article [1] contained displaced depiction of confidence intervals within the Bland-Altman plots in Figs. 1 and 2, which have been adjusted. Additionally, the corresponding titles of the plots were interchanged in the initial version of the manuscript and have been corrected accordingly. The updated figures (Figs. 1 and 2) are published in this corrected article.

Fig. 1
figure 1

Bland–Altman comparison of the measured diameters of the pulmonary arteries assessed by modified REACT-non-CE-MRA and 4D CE-MRA. The middle line indicates the mean bias of the diameter measurements whereas the dotted lines represent the 95% confidence interval. Values are given in mm

Fig. 2
figure 2

Bland–Altman comparison of the measured diameters of the pulmonary veins assessed by modified REACT-non-CE-MRA and 4D CE-MRA. The middle line indicates the mean bias of the diameter measurements whereas the dotted lines represent the 95% confidence interval. Values are given in mm

Reference

  1. Pennig L, Wagner A, Weiss K, et al. Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography. J Cardiovasc Magn Reson. 2020;22:8. https://doi.org/10.1186/s12968-019-0591-y.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lenhard Pennig.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pennig, L., Wagner, A., Weiss, K. et al. Correction to: Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel Compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography. J Cardiovasc Magn Reson 22, 16 (2020). https://doi.org/10.1186/s12968-020-00606-2

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s12968-020-00606-2