209 MRI cardiac catheter assessment of total and differential pulmonary vascular resistance in the context of single ventricle physiology

Introduction

In patients with complex cyanotic heart disease, pulmonary blood flow may be derived from more than one source, making assessment of pulmonary vascular resistance (PVR) difficult by conventional methods. Phase contrast MRI (PC-MRI) combined with invasive cardiac catheterization enables accurate measurement of the PVR. We demonstrate the application of MRI catheter in this patient group.

Hypothesis

MRI Cardiac catheter can assess the PVR in these patients, including those with multiple sources of pulmonary blood flow.

Methods

MRI cardiac catheterisation was performed in a combined XMR suite with a Philips 1.5 T Intera Achieva MR scanner and a single plane cardiac X-Ray unit. All patients underwent MRI cardiac catheter under general anaesthesia and were ventilated to normocarbia. Simultaneous pressure measurements were obtained with PC-MRI according to the vascular anatomy. Differential pulmonary blood flow was measured distal to all sources of blood flow. For those patients with multiple sources of blood flow, PVR was calculated by the equation: 1/PVRtotal = 1/PVRleft + 1/PVRright. Data is expressed as mean (± standard deviation), means are compared with a 2-tailed t-test.

Results

Twenty MRI cardiac catheters were performed in 18 patients with complex cyanotic disease, median age 3.63 years (0.5 to 41.7). For all patients, the mean PVR was 2.95 WU.m2 (± 1.41). Differential PVR was measured in 11 patients, the mean PVRright was 6.70 (± 2.01) WU.m2 and was significantly elevated compared to the mean PVRleft of 3.49 (± 1.12) WU.m2 (p = 0.002). Seven of these patients had multiple sources of pulmonary blood flow (Table 1). Seventeen patients were being investigated for suitability for progression to the next stage of cavo-pulmonary connection, 11 patients were suitable and 6 were unsuitable. The mean PVR or those suitable was 2.35 WU.m2 (± 0.58) compared to 4.54 WU.m2 (± 1.57), p = 0.017, for those who were unsuitable for further cavo-pulmonary palliation. The remaining three patients underwent assessment for complications related to the fontan circuit, the mean PVR was 2.14 in this group.

Table 1 Patients with multiple sources of pulmonary blood flow. MRI Cardiac Catheter allows for the measurement of pulmonary vascular resistance in patients with complex congenital heart disease. Differential pulmonary vascular resistance can be measured when there are multiple sources of pulmonary blood flow.

Conclusion

In patients with a single ventricle physiology, the PVR needs to be low in order to proceed with palliation by means of a cavo-pulmonary connection. This can be determined by MRI cardiac catheter. Additionally, this technique offers the advantage of being able to measure the differential pulmonary vascular resistance, even in the context of multiple sources of pulmonary blood flow. We have found a difference in the mean PVR between the right and left lungs, which merits further investigation.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Bell, A.J., Greil, G., Beerbaum, P. et al. 209 MRI cardiac catheter assessment of total and differential pulmonary vascular resistance in the context of single ventricle physiology. J Cardiovasc Magn Reson 10 (Suppl 1), A70 (2008). https://doi.org/10.1186/1532-429X-10-S1-A70

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-10-S1-A70

Keywords