Cardiovascular magnetic resonance evaluation of symptomatic severe aortic stenosis: association of circumferential myocardial strain and mortality
Journal of Cardiovascular Magnetic Resonance volume 19, Article number: 13 (2017)
Abstract
Background
It is unknown whether circumferential strain is associated with prognosis after treatment of aortic stenosis (AS). We aimed to characterise strain in severe AS, using myocardial tagging cardiovascular magnetic resonance (CMR), prior to and following Transcatheter Aortic Valve Implantation (TAVI) and Surgical Aortic Valve Replacement (SAVR), and determine whether abnormalities in strain were associated with outcome.
Methods
CMR was performed pre- and 6 m post-intervention in 98 patients (52 TAVI, 46 SAVR; 77 ± 8 years) with severe AS. TAVI patients were older (80.9 ± 6.4 vs. 73.0 ± 7.0 years, p < 0.01) with a higher STS score (2.06 ± 0.6 vs. 6.03 ± 3.4, p < 0.001). Tagged cine images were acquired at the basal, mid and apical LV levels with a complementary spatial modulation of magnetization (CSPAMM) pulse sequence. Circumferential strain, strain rate and rotation were calculated using inTag© software.
Results
No significant change in basal or mid LV circumferential strain, or of diastolic strain rate, was seen following either intervention. However, a significant and comparable decline in LV torsion and twist was observed (SAVR: torsion 14.08 ± 8.40 vs. 7.81 ± 4.51, p < 0.001, twist 16.17 ± 7.01 vs.12.45 ± 4.78, p < 0.01; TAVI: torsion 14.43 ± 4.66 vs. 11.20 ± 4.62, p < 0.001, twist 16.08 ± 5.36 vs. 12.36 ± 5.21, p < 0.001) which likely reflects an improvement towards normal physiology following relief of AS. Over a maximum 6.0y follow up, there were 23 (16%) deaths following valve intervention. On multivariable Cox analysis, baseline mid LV circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01–1.05; p = 0.009) independent of age, LV ejection fraction and STS mortality risk score. ROC analysis indicated a mid LV circumferential strain > −18.7% was associated with significantly reduced survival.
Conclusion
TAVI and SAVR procedures are associated with comparable declines in rotational LV mechanics at 6 m, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain is associated with post-operative mortality.
Background
Degenerative aortic valve stenosis (AS) is the commonest valvular disease in the western world currently affecting 3% of people over 75 years [1]. The left ventricle (LV) responds to pressure overload from aortic stenosis with hypertrophy to offset increased wall stress, in accordance with Laplace’s law [2]. This involves adverse remodelling of the extracellular matrix and altered protein composition which initially leads to a regional reduction in myocardial deformation, with global impairment in contraction occurring later [3].
Myocardial strain, strain rate and twist allow more sensitive characterisation of subtle myocardial performance [4] and can all be objectively quantified using myocardial tagging CMR with proven reproducibility [5, 6]. The myocardium deforms simultaneously in 3 directions and strain measurements can detect pathology prior to decline in conventional indices such as ejection fraction [7]. Patients with preserved cardiac output and severe AS reportedly exhibit compensatory high circumferential strain with increased apical rotation which are lost with decompensation of LV function [8].
Current guidelines recommend aortic valve replacement with the onset of symptoms or cardiac dysfunction (LVEF < 50%) [9]. However, impaired LVEF is a late change indicating significant myocardial damage and poorer outcomes, even after correction of AS [10]. It is notable LVEF is normal in most patients with severe AS, even when symptoms develop and that valve area and transvalvular gradients do not predict clinical outcomes following AVR [11]. The prognostic importance of circumferential myocardial strain in particular on outcome after treatment of aortic stenosis is unknown.
The aims of this study were to 1) characterise LV systolic and diastolic function as measured by CMR tagging in patients with severe symptomatic aortic stenosis prior to and following TAVI and SAVR, and 2) to assess whether CMR measures of strain could hold prognostic importance in those undergoing intervention.
Methods
Study population
146 patients were prospectively recruited with severe trileaflet degenerative AS who were referred for either TAVI (n = 91) or SAVR (n = 55) at the University Hospitals of Leeds and Leicester, UK, between July 2008 and December 2013. Severe AS was classified by transthoracic echocardiography (TTE) as an aortic valve area of ≤1.0 cm2 or peak velocity >4 m/s. The decision for TAVI or SAVR was taken by a multidisciplinary heart team in accordance with international guidance. Higher-risk (higher STS score) SAVR patients were recruited in preference to ensure baseline demographics were more comparable to the TAVI group. Exclusion criteria included any contraindication to CMR. Five age-comparable healthy controls were also scanned for comparison.
Transcatheter aortic valve replacement
TAVI was performed under general anaesthesia. Either an 18 F CoreValve Revalving system (CVR, Medtronic, Minneapolis, Minnesota, USA) or an 18 or 20 F Lotus™ Aortic Valve system (Boston Scientific Corporation, Natick, MA, USA) were deployed as previously described [12, 13]. A transfemoral route was used preferentially when vascular access was suitable. In the presence of significant peripheral vascular disease, a subclavian artery approach was performed. The invasively measured LV end diastolic pressure was recorded from procedural details.
Surgical aortic valve replacement
SAVR was performed by standard midline sternotomy with cardiopulmonary bypass and mild hypothermia. Biological or mechanical prostheses of varying sizes were used according to surgical preference; concomitant coronary artery bypass grafting was performed as indicated.
CMR protocol
For each patient, identical preoperative and 6 m postoperative scans were performed on the same 1.5 T MRI vendor platform (Intera, Phillips Healthcare, Best, Netherlands or Avanto, Siemens Medical Systems, Erlangen, Germany). Both sites used the identical CMR protocol as previously described [14]; in brief this comprised standard steady-state free procession pulse sequences to image the entire left and right ventricle, through-plane velocity encoded phase contrast imaging to quantify aortic valve function and late gadolinium enhancement imaging 10 min after the administration of 0.2 mmol/kg of gadoteric acid to assess for fibrosis.
Complementary spatial modulation of magnetisation (CSPAMM) imaging was carried out during a single breath hold at end expiration in the short axis orientation, at the apex, mid-, and basal LV (multishot echo planar imaging, flip angle sweep applied to the radiofrequency excitation pulses of subsequent cardiac phases, two orthogonal line tags acquired per slice, field of view: 300 mm, matrix 128 × 128, slice thickness 10 mm, tag separation 8 mm, typically 18 phases, repetition time/echo time [TR/TE] 30 ms/6 ms, flip angle 25°). The “3 of 5 technique” was used to minimize variation in slice positioning between visits and has been demonstrated to be highly reproducible [5].
Image analysis
All analysis was performed blinded off-line, using commercially available software (QMass 7.5 and QFlow 7.2, Medis Medical Imaging Systems, Leiden, The Netherlands). Standard ventricular and valvular assessment was performed as previously described [14]. Late gadolinium enhancement images were reviewed by two experienced observers for focal myocardial fibrosis and scarring (secondary to infarction) and reported qualitatively, as either present or absent, and then quantified using the full-width half-maximum technique.
CSPAMM analysis was performed for each myocardial slice using a dedicated tagging analysis package (inTag© software, Creatis, Lyon, Fr) and an example is depicted in an additional figure (see Additional file 1: Figure S1). Endocardial and epicardial contours were drawn for each slice, and a mid-myocardial contour was automatically calculated; contours were propagated through all cardiac phases. Strain is defined as an index that refers to the amount of myocardial deformation in one direction normalised to its initial dimension. Strain rate is the rate of deformation within in a time unit [2, 4]. Circumferential Lagrangian strain and strain rates (between epicardial and endocardial contours) and rotation were calculated for the three short axis slices. Left ventricular twist was determined as the difference between rotation at the apex and rotation at the base. Torsion was calculated as twist corrected for by length and radius of the LV cavity.
Intra-observer (12 data sets 6 months apart) and inter-observer (12 data sets) agreement was assessed using the intra-class correlation coefficient.
Statistical analysis
Continuous variables are presented as mean ± SD. Normality was determined by the Shapiro–Wilk test. Frequencies are reported as number (%). The Student t test and Wilcoxon signed rank test were used to compare continuous variables as appropriate, and χ2 or Fisher’s exact test for categorical comparisons. Changes over time were assessed for differences between the treatment groups and clinical variables by two-way repeated measures analysis of variance (ANOVA). Cox proportional-hazards ratio regression analyses were performed to investigate univariate and multivariate correlates of all-cause mortality. Hazard ratios and 95% confidence intervals (CIs) were reported. Variables with univariate p < 0.05 were entered in the multivariate analysis in a stepwise forward approach. Receiver operating characteristic (ROC) curves were constructed to assess the sensitivity and specificity predictor variables. The cumulative event rates were calculated on the basis of the Kaplan-Meier method, and comparisons between groups were assessed by log-rank test. All statistical analyses were performed using the PASW software package (V.21.0 SPSS, IBM, Chicago, Illinois, USA) with the exception of ROC analysis that was performed with MedCalc version 9.3.1 (MedCalc Software, Mariakerke, Belgium). A two-sided significance level of p < 0.05 was considered statistically significant.
Results
Ninety-eight patients (52 TAVI, 46 SAVR) with paired pre-operative and 6 m post-operative CMR scans were included for analysis. Reasons for non-completion of the CMR protocol were varied and are depicted in Fig. 1. At baseline, 15 patients did not undergo late gadolinium enhancement (LGE) imaging due to impaired renal function. Baseline characteristics of the study population are shown in Table 1 and grouped according to treatment received. As expected the TAVI group were older with a higher predicted 30 day mortality and greater frequency of prior coronary artery intervention.
Measurement variability
Calculation of intra-class correlation coefficients indicated good intra- and inter-observer reproducibility of CMR measurements respectively: circumferential strain (0.98, 0.96) and LV twist (0.97, 0.95).
Procedural data
Procedural data for TAVI and SAVR are summarised in an additional file (see Additional file 2: Table S1). For TAVI, 40(77%) patients received a Medtronic CoreValve and 12(23%) a Boston Scientific Lotus valve. A 29 mm valve was the most frequently used size (n = 26, 50%). In the surgical group, six patients received a mechanical prosthesis and the remaining 40(87%) a tissue bioprosthesis from various manufacturers. The modal valve size was 23 mm (n = 17, 37%). Twelve (26%) patients received concomitant coronary bypass grafting.
Aortic Valve Haemodynamics and LV reverse remodelling
Results of the baseline and 6 m CMR scans are shown in Table 2. Significant reductions in peak aortic valve pressure gradient resulted in comparable reverse remodelling post-SAVR and TAVI; with reductions in both indexed LV EDV and mass.
Measures of strain by CMR
At baseline, both groups undergoing SAVR and TAVI had comparable LV circumferential strain of the base (p = 0.081) mid (p = 0.128) and apex (0.318) with overall preserved LV ejection fraction. Similarly LV torsion (p = 0.845) and twist (p = 0.879) were comparable between groups. However, both systolic (p = 0.039) and diastolic (p = 0.037) strain rates were higher in the SAVR group.
At baseline for the TAVI group, there was moderate correlation between increasing LV end diastolic pressure (measured invasively during TAVI implantation) and both a deterioration in peak basal circumferential strain (r = 0.4, n = 33, p = 0.04, two-sided) and diastolic peak mid-ventricular strain rate (r = −0.5, n = 33, p = 0.003, two-sided).
No significant change in basal or mid-LV circumferential strain or of diastolic strain rate was seen following intervention, either post-SAVR or TAVI. A significant decline in peak apical circumferential strain following SAVR and an increase in circumferential systolic strain rate following TAVI were noted.
Both SAVR and TAVI were associated with a significant and comparable decline in LV twist and torsion at 6 months following intervention (Fig. 2) consistent with normalisation towards physiological values (Table 3).
Analysing the total severe AS patient population (n = 98), no change in LV strain at any level was seen following aortic valve intervention (Base: −0.186 ± 0.056 vs. −0.186 ± 0.054, p = 0.961; Mid: −0.201 ± 0.058 vs. −0.199 ± 0.006, p = 0.714; Apex: −0.194 ± 0.065 vs. −0.182 ± 0.064, p = 0.05).
Predictors of mortality following intervention
Over a maximum 6.0y follow up (median 2.5 years); there were 23 deaths (all-cause, of which 14 had completed follow-up imaging). Stepwise logistic regression identified a number of demographics and measures of cardiac function that were associated with mortality. Notably, the presence of baseline myocardial fibrosis (detected by LGE imaging), indexed LV mass, mean aortic pressure gradient and history of myocardial infarction were not significantly associated with prognosis. In multivariate analysis, baseline mid LV circumferential strain remained independently associated with all-cause mortality (Table 4). ROC analysis indicated the optimal threshold for pre-procedure mid LV circumferential strain to be −18.7%, from which a Kaplan-Meier graph was derived (Fig. 3).
Discussion
This prospective multicentre study has demonstrated that in severe symptomatic AS patients with abnormal strain and torsion, a reduction in torsion but no recovery in circumferential strain is seen post-valve replacement (with either TAVI or SAVR). In addition, reduced baseline mid-LV circumferential strain was associated with a higher post-operative mortality, independent of age, STS predicted mortality and LVEF.
Previous studies in patients with symptomatic severe AS and preserved LV ejection fraction have reported uniformly reduced longitudinal strain [15–18]. Sustained severe AS culminates in hypertrophic LV remodelling and an elevation in LVEDP. This predisposes to subendocardial ischaemia and impairs longitudinal subendocardial fibre contractility [19] reducing global systolic function [20]. Our study is the first to define an inverse relationship between invasively measured LVEDP and CMR derived circumferential strain and diastolic strain rate in aortic stenosis.
Higher circumferential strain in patients with preserved LVEF, and increased apical rotation in patients with mild LV dysfunction are thought to indicate compensatory mechanics serving to maintain radial strain. These compensatory mechanisms are reduced as LV performance declines (8) and their loss appears to occur at the time of symptom onset [19] indicating their potential use for surveillance and timing of surgery [21].
At baseline, our severe AS population had abnormally low circumferential strain with normal twist values compared with echocardiography derived reference ranges [22]. This is indicative of failing dynamic LV compensation consistent with their symptomatic status, despite an overall preserved LVEF. Our findings are thus a novel contribution, distinct from prior published work [8, 23–25], in reporting the impact of treatment in a study population with more advanced LV dysfunction as a consequence of severe AS.
Our study population had particularly severe indices of AS severity and the observed reduced baseline strain may reflect diminished coronary flow reserve [23] and repetitive ischaemic myocardial injury [24]. Improved valvular function following intervention is thought to confer improved transmural myocardial perfusion and subsequent improved LV mechanics [26] but this was not seen in our study; neither following TAVI, SAVR, or as a treated AS population in its entirety. It is notable coronary heart disease is thought to blunt recovery of myocardial mechanics following SAVR [27]. In a sub analysis of our entire AS population excluding those with diseased epicardial vessels, we still failed to observe any improvement in circumferential strain at any LV level following treatment.
Conflicting changes in LV strain rates have been reported, with both improvements [17, 26, 28] and a decline (25) following SAVR; and either no change [24] or an improvement following TAVI [29]. Our study demonstrates neither SAVR nor TAVI was associated with improvement of peak circumferential strain at any level, or of diastolic strain rate. In a sub analysis of our entire AS population excluding those with late gadolinium enhancement, we still failed to observe any improvement in circumferential strain at any LV level following treatment. This lack of improvement indicates a degree of irreversible decompensation at baseline which may have potential future implications for surveillance of systolic function and timing of intervention in severe AS.
Our study provides unique insight into the assessment of LV rotational mechanics, which remains largely unaddressed by previous studies; both in the context of symptomatic AS and following aortic valve intervention. LV torsion and twist are integral components of ventricular contractility and diastolic filling [30]. Previous CMR studies have reported changes in rotation in the context of AS, but inferences were confounded by very small sample sizes (largest n = 13) [31, 32]. An increase in LV twist has been described in severe AS with preserved LVEF as compensation for impaired systolic longitudinal function [27]. The baseline LV twist in our patients was notably lower than those awaiting SAVR from published echo studies [33], again suggesting failure of compensation and a more advanced stage of disease [29].
Our study indicates that significant and comparable reductions in both torsion and twist, similar to that reported by others, occurs following SAVR [33] and TAVI [29]. Twist is an energy saving process reflecting the helical orientation of cardiac fibres which offsets afterload mismatch, generating high intra-cavity pressure with minimal fibre shortening [31]. In the context of AS and increased afterload, enhanced LV twist and torsion are observed to preserve adequate LV filling and untwisting [33–35]. Torsion is dependent on LV shape and falls with declining concentric hypertrophy, representing reduced leverage from epicardial fibres [36]. In our study, both TAVI and SAVR precipitated comparable reverse LV remodelling with significant reductions in both indexed LVEDV and LV mass. This is mechanistically consistent with our observed decline in twist and torsion which likely reflects an improvement in rotational mechanics towards more normal values.
Patients with severe aortic stenosis and reduced LV ejection fraction carry a high risk of mortality following both SAVR [37] and TAVI [38]. However, deteriorating ejection fraction is a late occurrence and significant interest remains in identifying advanced objective predictors of mortality when ejection fraction is above 50%. This study is, to our knowledge, the first to demonstrate circumferential strain derived by CMR is independently associated with all-cause postoperative mortality in symptomatic patients with severe AS and preserved LVEF undergoing intervention.
Previous studies have hypothesised the prognostic value of longitudinal strain in AS may reflect the impact of myocardial fibrosis and provide the link to poor outcome [39, 40]. This study has tested for an association between myocardial fibrosis and strain with respect to outcome, and demonstrates the prognostic importance of circumferential strain measurement is unrelated to late gadolinium enhancement. Lower circumferential strain in severe AS is independently associated with myocardial triglyceride accumulation [41]. It is possible this lipotoxicity, which is undetectable using conventional LGE imaging, is important to the link between strain and outcome. However, our findings are not fully explicable by myocardial steatosis which has been shown to regress following SAVR, albeit in younger patients than our study [41].
Based on our work, patients with severe AS, even in the context of preserved LVEF, are at high risk for mortality when baseline mid-LV circumferential strain is > −18.7%. It is noteworthy this association occurs despite the relief of index aortic stenosis with SAVR or TAVI, and thus these patients in particular may benefit from greater scrutiny in follow-up. Measurement of circumferential strain using CMR is a non-invasive and reproducible modality by which a single, breath-held acquisition can potentially provide prognostic information independent of age, LVEF and surgical risk score.
Limitations
Our study population included patients with coronary artery disease and hypertension, rather than being restricted to pure aortic stenosis. This is however, generalisable to real world clinical practise and reduces the effect of selection bias. CMR assessment of cardiac rotational mechanics is sensitive to atrial fibrillation and regional wall motion abnormalities which can impair image quality. However, our quantification of strain using myocardial tagging CMR has demonstrated good reproducibility [5].
The control group comprised only 5 patients and ideally a larger sample would have facilitated a more robust comparison. There is paucity in the literature in regards to normal CMR strain ranges particularly in patients aged 80 years and above as it is challenging to recruit volunteers with structurally normal hearts from this age group.
Our study population size is small with relatively few events carrying a risk of potential statistical over fitting. Also, we have reported all-cause mortality rather than cardiac mortality. Thus our findings need to be viewed with caution and validated in larger outcome studies. The regression analysis was aimed at identifying factors associated with persistently poor outcomes after aortic stenosis has already been relieved; thus our results relate to a specific patient population and should not be over-generalised. Finally, we only enrolled patients with symptomatic aortic stenosis and further work is required to determine whether the prognostic importance of strain assessment can be extended to those who are asymptomatic; and thus potentially influence surgical timing.
Conclusions
Patients with symptomatic severe AS and preserved LVEF undergoing aortic valve intervention have reduced peak circumferential strain and systolic strain rates. At 6 m, TAVI and SAVR procedures were associated with comparable declines in rotational LV mechanics, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain was associated with post-operative total mortality and requires further investigation as to its use as a risk stratification tool.
Abbreviations
- AR:
-
Aortic regurgitation
- AS:
-
Aortic stenosis
- AVA:
-
Aortic valve area
- BMI:
-
Body mass index
- CABG:
-
Coronary artery bypass grafting
- CMR:
-
Cardiovascular magnetic resonance
- COPD:
-
Chronic obstructive pulmonary disease
- CSPAMM:
-
Complementary spatial modulation of magnetisation
- eGFR:
-
estimated glomerular filtration rate
- EuroSCORE:
-
European System for Cardiac Operative Risk Evaluation
- LGE:
-
Late gadolinium enhancement
- LVEDP:
-
Left ventricular end diastolic pressure
- LVEF:
-
Left ventricular ejection fraction
- LVM:
-
Left ventricular mass
- MI:
-
Myocardial infarction
- MPG:
-
Mean pressure gradient
- MR:
-
Mitral regurgitation
- NYHA:
-
New York Heart Association
- PCI:
-
Percutaneous coronary intervention
- ROC:
-
Receiver operating characteristic
- SAVR:
-
Surgical aortic valve replacement
- STS:
-
Society of Thoracic Surgeons’ risk models
- TAVI:
-
Transcatheter aortic valve implantation
- Zva:
-
Valvuloarterial impedance
References
Iung B, Vahanian A. Degenerative calcific aortic stenosis: a natural history. Heart. 2012;98 Suppl 4:iv7–13.
Ozkan A, Kapadia S, Tuzcu M, Marwick TH. Assessment of left ventricular function in aortic stenosis. Nat Rev Cardiol. 2011;8:494–501.
Kaden JJ, Dempfle CE, Grobholz R, et al. Interleukin-1 beta promotes matrix metalloproteinase expression and cell proliferation in calcific aortic valve stenosis. Atherosclerosis. 2003;170:205–11.
Wang B, Chen H, Shu X, et al. Emerging role of echocardiographic strain/strain rate imaging and twist in systolic function evaluation and operative procedure in patients with aortic stenosis. Interact Cardiovasc Thorac Surg. 2013;17:384–91.
Swoboda PP, Larghat A, Zaman A, et al. Reproducibility of myocardial strain and left ventricular twist measured using complementary spatial modulation of magnetization. J Magn Reson Imaging. 2014;39:887–94.
Singh A, Steadman CD, Khan JN, et al. Intertechnique agreement and interstudy reproducibility of strain and diastolic strain rate at 1.5 and 3 Tesla: a comparison of feature-tracking and tagging in patients with aortic stenosis. J Magn Reson Imaging. 2015;41:1129–37.
Galli E, Lancellotti P, Sengupta PP, Donal E. LV mechanics in mitral and aortic valve diseases: value of functional assessment beyond ejection fraction. J Am Coll Cardiol Img. 2014;7:1151–66.
Carasso S, Cohen O, Mutlak D, et al. Relation of myocardial mechanics in severe aortic stenosis to left ventricular ejection fraction and response to aortic valve replacement. Am J Cardiol. 2011;107:1052–7.
Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012): the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg. 2012;42:S1–44.
Vaquette B, Corbineau H, Laurent M, et al. Valve replacement in patients with critical aortic stenosis and depressed left ventricular function: predictors of operative risk, left ventricular function recovery, and long term outcome. Heart. 2005;91:1324–9.
Hachicha Z, Dumesnil JG, Bogaty P, Pibarot P. Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival. Circulation. 2007;115:2856–64.
Piazza N, Grube E, Gerckens U, et al. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008;4:242–9.
Meredith IT, Worthley SG, Whitbourn RJ, et al. Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study. EuroIntervention. 2014;9:1264–70.
Fairbairn TA, Steadman CD, Mather AN, et al. Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study. Heart. 2013;99:1185–91.
Pibarot P, Dumesnil JG. Longitudinal myocardial shortening in aortic stenosis: ready for prime time after 30 years of research? Heart. 2010;96:95–6.
Attias D, Macron L, Dreyfus J, et al. Relationship between longitudinal strain and symptomatic status in aortic stenosis. J Am Soc Echocardiogr. 2013;26:868–74.
Becker M, Kramann R, Dohmen G, et al. Impact of left ventricular loading conditions on myocardial deformation parameters: analysis of early and late changes of myocardial deformation parameters after aortic valve replacement. J Am Soc Echocardiogr. 2007;20:681–9.
Iwahashi N, Nakatani S, Kanzaki H, Hasegawa T, Abe H, Kitakaze M. Acute improvement in myocardial function assessed by myocardial strain and strain rate after aortic valve replacement for aortic stenosis. J Am Soc Echocardiogr. 2006;19:1238–44.
Lancellotti P, Donal E, Magne J, et al. Impact of global left ventricular afterload on left ventricular function in asymptomatic severe aortic stenosis: a two-dimensional speckle-tracking study. Eur J Echocardiogr. 2010;11:537–43.
Ross Jr J. Afterload mismatch and preload reserve: a conceptual framework for the analysis of ventricular function. Prog Cardiovasc Dis. 1976;18:255–64.
Carasso S, Mutlak D, Lessick J, Reisner SA, Rakowski H, Agmon Y. Symptoms in severe aortic stenosis are associated with decreased compensatory circumferential myocardial mechanics. J Am Soc Echocardiogr. 2015;28:218–25.
Kaku K, Takeuchi M, Tsang W, et al. Age-related normal range of left ventricular strain and torsion using three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr. 2014;27:55–64.
Biederman RW, Doyle M, Yamrozik J, et al. Physiologic compensation is supranormal in compensated aortic stenosis: does it return to normal after aortic valve replacement or is it blunted by coexistent coronary artery disease? An intramyocardial magnetic resonance imaging study. Circulation. 2005;112:I429–36.
Grabskaya E, Becker M, Altiok E, et al. Impact of transcutaneous aortic valve implantation on myocardial deformation. Echocardiography. 2011;28:397–401.
Carasso S, Cohen O, Mutlak D, et al. Differential effects of afterload on left ventricular long- and short-axis function: insights from a clinical model of patients with aortic valve stenosis undergoing aortic valve replacement. Am Heart J. 2009;158:540–5.
Delgado V, Tops LF, van Bommel RJ, et al. Strain analysis in patients with severe aortic stenosis and preserved left ventricular ejection fraction undergoing surgical valve replacement. Eur Heart J. 2009;30:3037–47.
Meimoun P, Elmkies F, Benali T, et al. Assessment of left ventricular twist mechanics by two-dimensional strain in severe aortic stenosis with preserved ejection fraction. Ann Cardiol Angeiol (Paris). 2011;60:259–66.
Rost C, Korder S, Wasmeier G, et al. Sequential changes in myocardial function after valve replacement for aortic stenosis by speckle tracking echocardiography. Eur J Echocardiogr. 2010;11:584–9.
Poulin F, Carasso S, Horlick EM, et al. Recovery of left ventricular mechanics after transcatheter aortic valve implantation: effects of baseline ventricular function and postprocedural aortic regurgitation. J Am Soc Echocardiogr. 2014;27:1133–42.
Sengupta PP, Tajik AJ, Chandrasekaran K, Khandheria BK. Twist mechanics of the left ventricle: principles and application. J Am Coll Cardiol Img. 2008;1:366–76.
Nagel E, Stuber M, Burkhard B, et al. Cardiac rotation and relaxation in patients with aortic valve stenosis. Eur Heart J. 2000;21:582–9.
Stuber M, Scheidegger MB, Fischer SE, et al. Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation. 1999;100:361–8.
Lindqvist P, Zhao Y, Bajraktari G, Holmgren A, Henein MY. Aortic valve replacement normalizes left ventricular twist function. Interact Cardiovasc Thorac Surg. 2011;12:701–6.
Pasipoularides A. LV twisting and untwisting in HCM: ejection begets filling. Diastolic functional aspects of HCM. Am Heart J. 2011;162:798–810.
van Dalen BM, Tzikas A, Soliman OI, et al. Left ventricular twist and untwist in aortic stenosis. Int J Cardiol. 2011;148:319–24.
Young AA, Cowan BR. Evaluation of left ventricular torsion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2012;14:49.
Monin JL, Quere JP, Monchi M, et al. Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics. Circulation. 2003;108:319–24.
Sannino A, Gargiulo G, Schiattarella GG, et al. Increased mortality after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and low ejection fraction: a meta-analysis of 6898 patients. Int J Cardiol. 2014;176:32–9.
Dahl JS, Videbaek L, Poulsen MK, Rudbaek TR, Pellikka PA, Moller JE. Global strain in severe aortic valve stenosis: relation to clinical outcome after aortic valve replacement. Circ Cardiovasc Imaging. 2012;5:613–20.
Kusunose K, Goodman A, Parikh R, et al. Incremental prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis and preserved ejection fraction. Circ Cardiovasc Imaging. 2014;7:938–45.
Mahmod M, Bull S, Suttie JJ, et al. Myocardial steatosis and left ventricular contractile dysfunction in patients with severe aortic stenosis. Circ Cardiovasc Imaging. 2013;6:808–16.
Acknowledgements
We thank Mrs Fiona Richards, Mrs Lisa Clark and Ms Petra Bijsterveld for their assistance during the patient recruitment process.
Funding
This study was part-funded by the British Heart Foundation (PG/11/126/29321) and also the National Institute for Health Research (NIHR) Leeds Clinical Research Facility. GPM is supported by a NIHR career development fellowship. The views expressed are those of the author(s) and not necessarily those of the NHS, NIHR or the Department of Health. Authors were otherwise funded by the Universities of Leeds and Leicester, UK.
Availability of data and materials
Not applicable.
Authors’ contributions
JPG conceived and designed the study. TAM, AU, TAF, CDS, AS and LED performed the recruitment of patients and data acquisition. DB carried out TAVI implantation. TAM, TAF, AU and PPS analysed MRI data and interpreted the results. PPS, PG and PH were involved in statistical analyses. TAM drafted the manuscript. JPG, SP and GM gave input into data interpretation. AK, DR, PS, AKM and BE were involved in critical and intellectual revision of the article. All authors edited and revised the manuscript. All authors read and approved the final manuscript.
Competing interests
DB is a proctor for the Medtronic CoreValve and Boston Scientific Lotus valve. No non-financial conflicts of interest exist for any of the authors.
Consent for publication
Not applicable.
Ethical approval and consent to participate
The study was approved by the national ethics committee (NRES Committee Yorkshire & the Humber – Leeds West, UK), complied with the Declaration of Helsinki and all patients provided written informed consent.
Author information
Authors and Affiliations
Corresponding author
Additional files
Additional file 1:
Figure S1. Example of inTag© analysis using CSPAMM. (DOCX 81 kb)
Additional file 2:
Table S1. Procedural and operative data for TAVI and SAVR procedures. (DOCX 30 kb)
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Musa, T.A., Uddin, A., Swoboda, P.P. et al. Cardiovascular magnetic resonance evaluation of symptomatic severe aortic stenosis: association of circumferential myocardial strain and mortality. J Cardiovasc Magn Reson 19, 13 (2017). https://doi.org/10.1186/s12968-017-0329-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12968-017-0329-7